Figure 5: Distance between drive/guide wheel to
saw band
Changing guide
The figure shows the bar of model SB295;
the procedure for changing the guide mechanism is
the same for models SB287, SB288 and SB295
If the gap is wider than 2.0 mm, change the fibre
guide (see Abb. 6).
Gap width max. 2.0
Figure 6: Changing guide
Removing guide from strip
To remove the guide from the strip, proceed as
follows:
Complete guide mechanism
Figure 7: Guide
Schmid & Wezel
D 75433 Maulbronn
Free rotation
Fibre guide
New: 0.6 mm
Page / Seite
19 / 39
1. Push guide up.
Figure 8: Guide pushed up.
2. Hold guide in top position.
Figure 9: Guide in top position
3. Remove the lever (64) from the holder.
Figure 10: Lever (64)
Figure 11: Removing lever from holder
Lever (64)
Lever (64)
Version/ Ausführung
09.2012