Operating conditions
The maximum permissible distance between the digital con-
troller/diverter of the functional unit or the transceiver is 5 m.
Sources of interferences
The transceiver operates in the ISM-frequency range
(2.4GHz). The installation in the vicinity of equipment with the
same channel occupancy (eg wireless devices, RF compo-
nents, etc. [observe the manufacturer´s documentation!])
should be avoided.
Obstructions/barriers
For operation under adverse environments, in buildings /
rooms with reinforced concrete walls, steel and iron frame, or
near of obstructions (eg furniture) of metal, the radio reception
can be disturbed and interrupted.
Kind of obstructions
Wood, synthetic material
Water, brick, marble
Plaster, concrete, glass, solid wood High
Metal
Technical data
• Radio frequency:
• Transmitter power:
• Digital controller/diverter battery:
3x 3 V lithium batteries (type CR 2450)
• Type of protection:
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature for ball impact test:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and
rated current.
Function F3 - Register/de-register additional (max. 3) digital controller (36 309)/diverter (48 113/48114).
Start of the function menu only when no water is flowing.
Button
Description
Start the function menu
- Select the function by simultaneously pressing and holding the - / + buttons.
- F3 Function select by turning the ring
• Start F3 - Register additional digital controller/diverter
=> Confirm by simultaneously pressing the - / + buttons.
- Press the buttons 1 + 3 of the additional digital controller/diverter
simultaneously in order to register it.
- Pressing the - / + buttons simultaneously on the pending digital controller
saves the selection and exits the menu.
• Start F3 - De-register additional digital controller/diverter
=> Confirm by simultaneously pressing the - / + buttons.
- Pressing the - / + buttons simultaneously on the factory digital controller to
de-register all additional controllers/diverters.
Abort the function menu by pressing and holding Start/Stopp button or after
3 minutes without triggering.
Disposal instructions
This category of device does not belong in the domestic waste, but must be disposed of separately in accordance
with the relevant local national regulations.
Dispose of batteries in accordance with national regulations.
43
Interference or
shielding potential
Low
Medium
Very high
2,4332 GHz (channel 5-6)
< 1 mW
IP X5
2500 V
212 °F
Approval and conformity
This device complies with part 15 of the FCC Rules and with
Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device
must accept any interference received, including interference
that may cause undesired operation.
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to
operate the equipment.
Insert batteries, see fold-out page I, Figs. [1] to [5].
Fasten digital controller/diverter, see fold-out page II,
Fig. [6a] or [6b] to [9].
Register digital controller (36 309)
After replacement, the new digital controller must first be
registered with the functional unit.
Proceed as follows for fittings:
1. Disconnect battery and power supply unit, see fold-out
page II, Fig. [10] or [11].
2. Wait approx. 10 seconds.
3. Reconnect battery and power supply unit. There are two
brief water pulses after 10 seconds.
4. Register the new digital controller within the next
60 seconds by simultaneously pressing On/Off and +.
5. The fitting is then ready for operation again.
Proceed as follows for thermostat boxes:
1. Disconnect power supply unit or, see fold-out page II,
Fig. [12].
2. Wait approx. 10 seconds.
B
3. Reconnect power supply unit or.
2
4. Wait 10 seconds. Register the new digital controller
within the next 60 seconds by simultaneously pressing
On/Off and +.
5. The thermostat box is ready for operation again after a total
of 3 minutes. The buttons on the digital controller/diverter
are inoperative during this time.
Visualization
Illuminated ring flashes red 1x.
Illuminated ring flashes red 3x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes violet 1x.