5 Installation of an insertion
1) Prior to installation of the insertion disconnect the
mains plug of the PA-1200EX from the mains
socket.
2) Screw off the corresponding cover panel (1 and/or
2) for the insertion compartment.
The three-pole connection cable for the insertion
module is fastened to the cover panel. Remove the
cable and connect it to the corresponding pin hous-
ing of the module (see operating instructions of the
module).
3) Install the insertion and tighten it with screws.
4) For all further installation steps refer to the operat-
ing instructions of the insertion used.
6 Connections
All connections should only be made by qualified,
skilled personnel and under any circumstances with
the unit switched off.
6.1 Connection to an amplifier
There are two possible ways to connect the unit to an
amplifier:
1. Connect the outputs PACK 1 (11) and PACK 2 (10)
separately to one line input each of the amplifier
(e. g. input for CD player, tape recorder). With the
volume controls of the insertions adjust the de sired
volume.
2. To feed the mixing signal of both insertions to the
amplifier, connect the output "1 + 2" (9) to a line
input of the amplifier. With the volume controls of
the insertions adjust the desired volume and the
mixing relation or carry out fading in and fading out.
6.2 Power supply and emergency power supply
1) For continuous operation of the amplifier in case
of a possible mains failure, connect a 24 V emer-
gency power supply unit (e. g. PA-24ESP from
MONACOR) to the terminals 24 V (8).
Note: If the 24 V voltage from the emergency
power unit is present at the terminals 24 V , the
amplifier cannot be switched off with the switch
POWER (4). In case of a mains failure or if it is
switched off, it is automatically switched to the
emergency power supply.
2) Finally plug the supplied mains cable to the mains
connecting jack (5) first and then to a mains socket
(230 V~/50 Hz).
All rights reserved by MONACOR
be reproduced in any form or by any means for any commercial use.
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
®

7 Specifications

Outputs
PACK 1: . . . . . . . . . . . . . 0 dBm, bal.
PACK 2: . . . . . . . . . . . . . 0 dBm, bal.
1 + 2: . . . . . . . . . . . . . . . 0 dBm, bal.
Power supply
mains voltage: . . . . . . . . 230 V~/50 Hz
power consumption: . . . . 55 VA
emergency
power supply: . . . . . . . . . 24 V
DC power consumption: . 2 A
Dimensions (W × H × D): . . 482 × 89 × 380 mm,
Weight: . . . . . . . . . . . . . . . . 4.5 kg
Subject to technical modification.