26
Connecting the IC20, IC40 Power Center to an
®
IntelliTouch
, EasyTouch
To operate IntelliChlor with the IntelliTouch, EasyTouch or SunTouch system, connect a four wire cable from
the IntelliChlor Power Center to the IntelliTouch, EasyTouch or SunTouch load center. Note: Only one
IntelliChlor cell can be installed per system. An alternate connection can be made by splicing anywhere
along the four wire connection that connects the IntelliTouch or EasyTouch indoor control panel to the load
center.
Note: See the following manuals for IntelliChlor operating instructions when connected to a Pentair
automation system:
- IntelliTouch User's Guide (P/N 521075)
- EasyTouch User's Guide" (P/N 521044)
- SunTouch User's Guide" (P/N 520785)
CAUTION - Wire the Power Center AC to the filter pump relay on the LOAD SIDE for maximum safety.
To connect IntelliChlor Power Center four wire cable to the IntelliTouch, EasyTouch or SunTouch load center:
WARNING - Switch OFF main system power to the Load Center before making any connections.
1. Remove the cover screw securing the Power Center cover. Remove the cover.
2. Run a UL approved four conductor cable (22 AWG) from the IntelliChlor Power Center to the Load
Center. The preferred wire color scheme is red, yellow, green, and black.
3. Remove the cover screw securing the Power Center cover. Remove the cover.
4. Remove one (1) of the knockouts from the underside of the Power Center.
5. Route the four conductor cable up through the lower hole.
6. Strip back the cable conductors ¼ in. Insert the wires into the screw terminals (provided in the kit).
Secure the wires with the screws. Make sure to match the color coding of the wires; Red = +15,
Yellow = +DT, Green = -DT, and GND = Black.
7. Plug the screw terminal onto the four (4) pins located on the Power Center board.
8. Reinstall the cover and secure with the cover screw.
9. Proceed to "Connecting IntelliChlor to an IntelliTouch System," on page 27, "Connecting IntelliChlor
to an EasyTouch System," on page 28, and "Connecting IntelliChlor to a SunTouch System," on
page 29.
Conduit knockout
IntelliChlor Electronic Chlorine Generator Installation and User's Guide
®
®
or SunTouch
IntelliChlor Power Center
(cover removed)
Automation System
Screw terminal
1
G
N
D
B
L
K
2
-
D
T
G
R
N
3
+
D
T
Y
E
L
4
1
5
V
R
E
D
Screw terminal
pin-outs

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Intellichlor ic40Intellichlor ic20

Inhaltsverzeichnis