Herunterladen Inhalt Inhalt Diese Seite drucken

Toshiba RAS-M07U2DVG-E Installationsanleitung Seite 4

Vorschau ausblenden Andere Handbücher für RAS-M07U2DVG-E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 80
ML.book Page 3 Wednesday, March 14, 2018 10:28 AM
• CONNECT THE CONNECTING CABLE CORRECTLY. IF THE
CONNECTING CABLE IS CONNECTED WRONGLY, ELECTRIC
PARTS MAY BE DAMAGED.
• CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR
DISCONNECTED BEFORE INSTALLATION.
• DO NOT INSTALL NEAR CONCENTRATIONS OF
COMBUSTIBLE GAS OR GAS VAPORS. FAILURE TO FOLLOW
THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION.
• TO PREVENT OVERHEATING THE INDOOR UNIT AND
CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY
(MORE THAN 2 M) FROM HEAT SOURCES SUCH AS
RADIATORS, HEATERS, FURNACE, STOVES, ETC.
• WHEN MOVING THE AIR CONDITIONER FOR INSTALLING IT IN
ANOTHER PLACE AGAIN, BE VERY CAREFUL NOT TO GET
THE SPECIFIED REFRIGERANT WITH ANY OTHER GASEOUS
BODY INTO THE REFRIGERATION CYCLE. IF AIR OR ANY
OTHER GAS IS MIXED IN THE REFRIGERANT, THE GAS
PRESSURE IN THE REFRIGERATION CYCLE BECOMES
ABNORMALLY HIGH AND IT RESULTINGLY CAUSES BURST
OF THE PIPE AND INJURIES ON PERSONS.
• IN THE EVENT THAT THE REFRIGERANT GAS LEAKS OUT OF
THE PIPE DURING THE INSTALLATION WORK, IMMEDIATELY
LET FRESH AIR INTO THE ROOM. IF THE REFRIGERANT GAS
IS HEATED BY FIRE OR SOMETHING ELSE, IT CAUSES
GENERATION OF POISONOUS GAS.
• WHEN INSTALLING OR RE-INSTALLING THE AIR
CONDITIONER, DO NOT INJECT AIR OR OTHER SUBSTANCES
BESIDES THE DESIGNATED REFRIGERANT "R32" INTO THE
REFRIGERATING CYCLE. IF AIR OR OTHER SUBSTANCES ARE
MIXED, AN ABNORMAL PRESSURE CAN OCCUR IN THE
REFRIGERATING CYCLE, AND THIS CAN CAUSE AN INJURY
DUE TO A PIPE RUPTURE.
EN-5
– 3 –
WARNING
• Installation work must be requested from the supplying retail
dealership or professional vendors. Self-installation may cause water
leakage, electrical shock, or fire as a result of improper installation.
• Specified tools and pipe parts for model R32 are required, and
installation work must be done in accordance with the manual.
Otherwise damage and/or injury may be caused. At the same time,
water leakage, electrical shock, and fire may occur.
• Be sure to install the unit in a place which can sufficiently bear its
weight. If the load bearing of the unit is not enough, or installation
of the unit is improper, the unit may fall and result in injury.
• Appliance and pipe-work shall be installed, operated and stored in
a room with a floor area lager than A
2
How to get A
m
= (M / (2.5 × 0.22759 × h
min
M is the refrigerant charge amount in appliance in kg;
h
is the installation height of the appliance in m;
0
0.6 m for floor standing/1.8 m for wall mounted/1.0 m for window
mounted/2.2 m for ceiling mounted.
For detail, refer to Installation Manual of the outdoor unit.
• Electrical work must be performed by a qualified electrical engineer
in accordance with the code governing such installation work,
internal wiring regulations, and the manual. A dedicated circuit and
the rated voltage must be used. Insufficient power supply or
improper installation may cause electrical shock or fire.
• Use a cabtyre cable to connect wires in the indoor/outdoor units.
Midway connection, stranded wire, and single-wire connections are
not allowed. Improper connection or fixing may cause a fire.
• Wiring between the indoor unit and outdoor units must be well
shaped so that the cover can be firmly placed. Improper cover
installation may cause increased heat, fire, or electrical shock at
the terminal area.
Installation Manual
2
m
min
2
))
0
EN-6

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis