Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
Cleaning the unit
If necessary, clean the unit with clear water using a soft brush.
− Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
− In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can
be used. Subsequently, clean the pump thoroughly using clear water.
Malfunctions
Trouble shooting
Unit does not run
Fountain height insufficient or
inconsistent
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!
Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the
regulations.

Wear parts

The impeller unit is a wearing part and does not fall under the warranty.
8
14405-04-13_GA_Aquarius Solar 708 8
Cause
- no voltage, 12 Volt
- Rotor blocked
- Sun energy insufficient
- Main flow regulator closed too far
- Nozzle blocked
- Filter/screen clogged
- Rotor soiled
- Hose blocked or defective
- Hose kinked
- Excessive loss due to friction in the hose
- Rotor worn
- Sun energy insufficient
Remedy
- Check voltage source
- Clean pump
- Adjust main flow regulator
- Clean nozzle
- Clean filter/screen
- Clean rotor
- Clean hose or replace
- Check hose and replace if necessary
- Reduce hose length to reduce frictional loss
- Replace rotor