-DMX512 Settings
The DNG-200 is equipped with a DMX512 system. For connecting a DMX controller, 3-pin
and 5-pin male-female XLR connections are provided at the back of the machine. The
machine uses one control channel for adjusting the output volume. The channel has a
DMX value range of 0 to 255. After connecting a DMX controller, timer functions such as
output duration and interval can be programmed using the DMX controller or the DMX
control software. The machine cannot be controlled via the D-20 control anymore. By
using the DMX protocol, fog machines, lighting effects, and other special effects machines
can be interconnected and easily controlled.
192 - 255 = high volume (60 % output)
127 - 191 = medium volume (52 % output)
32 - 126 = low volume (35 % output)
0 - 31 = off (no fog output)
Between the values 0 to 31 the machine does not have sufficient output volume and is off.
Between the values 31 to 126 the machine has a minimal output volume of 35%.
Between the values 127 to 191 the machine has a medium output volume of 52 %.
Between the values 191 to 255 the machine has a maximum output volume of 60 %.
-Operation Notice
After operation, please wait 15 minutes before turning off the machine.
Please do not turn the power on and off continuously. There must be at least a one-
minute interval between each power on and off.
Operate the machine in a well-ventilated area.
Do not position two or more DNG-200 machines side by side to prevent poor hot air
ventilation.
Do not operate the machine under direct sunlight.
It is strongly suggested not to have the machine produce continuous fog output over 20
minutes. Overtime usage might reduce the efficiency and lifespan of the compressor.
Please save this user manual carefully.