Herunterladen Inhalt Inhalt Diese Seite drucken

Settings And Adjustments - SIT 845 SIGMA Installationsanleitung

Vorschau ausblenden Andere Handbücher für 845 SIGMA:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33

SETTINGS AND ADJUSTMENTS

All adjustments must be made on the basis of the specific characteristics of the appliance. Check inlet and outlet
pressure using the pressure test points provided. After testing, carefully seal test points with the provided screws.
Recommended torque: 1.0 Nm.
Adjusting the outlet pressure
All the adjustments must be carried out in the following order:
Disconnect pressure regulator connection "VENT" (if used).
Remove the modulator plastic cap E.
• Maximum pressure: power the modulator in the maximum condition. Screw in the nut C to
increase the outlet pressure and screw it out to decrease it. 10 mm spanner
• Minimum pressure: cut off the power supply to the modulator and, keeping the nut C
blocked, screw in the screw D to increase the pressure and screw it out to decrease it. Screwdriver 6 x 1 blade.
Put back the modulator plastic cap.
Connect pressure regulator connection (if used).
WARNING:
to ensure the correct operation of the modulator it is necessary that the plastic cap E is returned to its
original location.
Gas family change
Check that the appliance is suitable for operation with the gas family in question. Adjust the minimum and maximum
outlet pressures in accordance with the values given in the appliance instruction booklet.
Changing gas group within the same family
Check that the appliance is suitable for operation with the gas group in question. Check in the appliance instruction
booklet if any operations are necessary when changing the gas group. If so, adjust the minimum and maximum gas
outlet pressures in accordance with the appliance manufacturer's instructions and as stated previously.
IMPORTANT: at the end of all setting and adjustment operations, check electrical insulation, gas seals and the
efficiency of the appliance. In particular, it is necessary to ensure that the flame does not go out and that light back
does not occur at the minimum and maximum gas outlet pressures. After carrying out all adjustments, fit the provided
seals and/or block the setting screws with paint, taking care not to obstruct the breather orifice of the pressure
regulator.
ACCESSORIES
Union joint for main gas connections
Main electric supply connector with 3 wires power
Main electric supply connector with 4 wires power
Modulating device electric supply connector.
E
C
D
GB
11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis