2. SPECIFICATIONS
2.1 Technical data for the heat pump unit GO'pac
Models
Heating capacity*
Absorbed electrical power
Running current*
Power supply
aM type fuse calibre
Curve D circuit breaker
Compressor quantity
Type of compressor
Fan quantity
Fan rotation speed
Fan power
Ventilation
Sound pressure level
(at 10 metre)
Hydraulic connection
Nominal water flow*
Water pressure drop (max)
Unit net dimensions (L/l/h)
Unit shipping dimensions (L/l/h)
Net weight / shipping weight
* Value at +/- 5% under the following conditions: Exterior temperature = 26°C (78.8°F) / HR = 81.5% /
Water inflow temperature = 26°C (78.8°F).
2
GO'pac
GOpac30
kW
6,5
kW
1,2
A
5,5
V
230V
Ph/Hz
50Hz
A
8
A
10
1
Rotatif
1
RPM
930/730
W
68/61
Horizontale Horizontale Horizontale Horizontale
dB(A)
32,6
mm
50
m
/h
2,9
3
kPa
3,5
mm
801/311/558
961/316/658
mm
890/355/600 1040/355/700 1040/355/700 1040/435/700
kg
42/49
GOpac40
GOpac50
8,8
10,7
1,6
1,9
7,1
8,7
230V
230V
50Hz
50Hz
10
12
10
12
1
1
Rotatif
Rotatif
1
1
850/620
850/620
115/90
115/90
33,3
34,7
50
50
3,8
4,6
4,0
4,3
961/316/658
55/63
60/68
GOpac60
12,9
2,3
11,9
230V
50Hz
16
16
1
Rotatif
1
850/620
115/90
37,2
50
5,2
4,8
961/396/658
70/80