Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
(flow limiter) located behind the aerator can be
removed.
Technical Data
This mixer series-produced with EcoSmart
limiter))
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Fault
Insufficient water
Crossflow, hot water being forced into
cold water pipe, or vice versa, when
mixer is closed
Instantaneous heater didn't work
Valve stiff / leaking
2
English
®
(flow
®
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min
Cause
- Supply pressure inadequate
- Filters are dirty
- Backflow preventers dirty or leaking
- Filters are dirty
- check valve hasn't moved back
- Supply pressure inadequate
- Select stop valve damaged / soiled
- Temperature limiter plugged on im-
properly
Assembly see page 4
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 6)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Dimensions (see page 8)
Flow diagram
(see page 9)
with EcoSmart
without EcoSmart
Operation (see page 9)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Maintenance (see page 10)
Spare parts (see page 11)
Cleaning (see enclosed brochure)
Remedy
- Check water pressure (If a pump
has been installed check to see if the
pump is working).
- Clean the filter / exchange filter
- Clean backflow preventers, ex-
change if necessary
- Clean the filter / exchange filter
- Exchange check valves
- Remove flow limiter
- Exchange Select stop valve
- Plug on the temperature limiter once
more (see page 6)
®
®

Werbung