Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens sitrans LR460 Schnellstartanleitung Seite 7

Vorschau ausblenden Andere Handbücher für sitrans LR460:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 51
Key considerations
• Nozzle design and nozzle location are critical to a successful application.
• Avoid reflective interference from vessel walls and obstructions by following the
guidelines below.
Nozzle design
• Bottom edge of horn must project from nozzle.
• Nozzle must have adequate clearance to allow LR460 to be positioned at an angle (see
Device orientation
top clamping plate
10 mm (0.38")
285 mm
(11.22")
Nozzle location
• Locate antenna at least 1 meter away from
side wall.
• Keep emission cone free of interference
from ladders, pipes, I-beams or filling
streams.
• Make allowance for beam spread to avoid
interference with the emission cone.
Device orientation
Align the antenna so that the radar cone is
perpendicular to the surface of the monitored
material, if possible.
Easy Aimer Installation
When the Easy Aimer ball is loosened,
Note:
the device is free to tilt to a maximum of 30°.
1.
Holding the electronics enclosure firmly,
loosen the Easy Aimer ball locking bolts and
gently reposition the enclosure (see
design
above).
2.
Direct SITRANS LR460 so the horn antenna
is pointed at an angle perpendicular to the material surface, if possible. (As a guide, aim
the beam at a point approximately 2/3 of the way across the tank diameter.)
3.
When the desired position is reached, re-tighten the 5 bolts to 15-23 N m (11 to 17 Lbf-ft).
7ML19985QW82
below).
bottom
clamping plate
customer-
supplied gasket
30 °
Nozzle
SITRANS LR460 – QUICK START MANUAL
Easy Aimer
ball locking
joints
min. clearance
10 mm (4")
min. 1 m (39")
Easy
Aimer
emission
cone
4" horn
3"
horn
11°
Page EN-5

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis