5
Programming the first individual point of control
- This operation can only be performed from the transmitter that was used for operation 4.1.
- Press the transmitter "PROG" Key for approximately one second. The motor will
run for 0,5 second in one direction and then in the other.
Your transmitter is now programmed to control the E SP Hz motor in
stable mode.
6
Programming a new (individual, group or main) control point
6.1- Open the memory of the receiver from the control transmitter:
- Press the "PROG" key of the transmitter for about three seconds. The
motor will run for 0,5 second in one direction, then in the other.
6.2 : Confirm the operation from the new transmitter you want to
programm:
- Press the "PROG" key of the transmitter for about one second. The
motor will run for 0,5 second in one direction, then in the other.
- For group controls, repeat operations 6.1 and 6.2 for each motor in the group.
- For general controls, repeat operations 6.1 and 6.2 for each motor in the installation.
- To delete an transmitter from the memory of a motor, perform operations 6.1 with a programmed transmitter,
then perform the operation 6.2 with the transmitter to be deleted.
7
Programming an EOSUN Hz VS automatic control
7.1- Open the memory of the motor using the individual control
transmitter:
- Press for about 3 seconds on the "PROG" key on the transmitter. The
motor will turn for 0,5 second in one direction, then in the other.
7.2- Confirm the operation from the EOSUN Hz VS automatic control to be
programmed:
- Press for about 1 second on the "PROG" key. The motor will turn for 0,5 second
in one direction, then in the other.
- If your automatic control is intended to control a group of motors: repeat operations 7.1 and 7.2 for each
motor in the group.
- To delete an automatic control from the motor's memory: Perform operation 7.1 from the individual control
transmitter and operation 7.2 from the automatic control to be deleted.
Recommandations when using EOSUN Hz VS Automatic device:
- If the automatic control on an installation is changed or deleted, it is important to delete it from the memory of
all the motors in which it was programmed.
>>
PROG 1s
>>
PROG 3s
>>
PROG 1s
>>
PROG 3s
>>
PROG 1s
3/4