Herunterladen Inhalt Inhalt Diese Seite drucken

HANSGROHE Showerpipe Croma 100 27154000 Gebrauchsanleitung, Montageanleitung Seite 7

Vorschau ausblenden Andere Handbücher für Showerpipe Croma 100 27154000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Maintenance (see page 65)
The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work
English
Cause
- Shower filter seal dirty
- Non return valve hasn't moved
back
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
- Filters are dirty
- Non return valve hasn't moved
back
- Flow limiter in handshower isn't
removed
Assembly see page 60
Cleaning (see page 70) enclosed
brochure
Spare parts (see page 72)
Test certificate (see page 68)
Remedy
- Clean filter seal between shower
and hose
- Exchange non return valves
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Clean the filter / exchange filter
- Exchange non return valves
- Remove flow limiter


Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Showerpipe croma 100 27155000

Inhaltsverzeichnis