Herunterladen Inhalt Inhalt Diese Seite drucken

Installation - Oase USP Classic 200 Gebrauchsanleitung

Wasserspielpumpe
Vorschau ausblenden Andere Handbücher für USP Classic 200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
− Ensure that the power connection cable cross section is not smaller than that of the rubber sheath with the identifi-
cation H05RN-F. Extension cables must meet DIN VDE 0620.
− Protect the plug connections from moisture.
− Only plug the unit into a correctly fitted socket.
Safe operation
− Never operate the unit if either the electrical cables or the housing are defective!
− Do not carry or pull the unit by its electrical cable.
− Route cords/hoses/lines in a way that they are protected against damage, and exclude that they present a tripping
obstacle.
− Only open the unit housing or its attendant components, when this is explicitly required in the operating instructions.
− Only execute work at the unit that is described in this manual. If problems cannot be overcome, please contact an
authorised customer service point or, when in doubt, the manufacturer.
− Only use original spare parts and accessories for the unit.
− Never carry out technical modifications to the unit.
− The power connection cables cannot be replaced. When the cable is damaged, the unit or the component needs to
be disposed of.
− Only operate the unit if no persons are in the water!
− Keep the socket and power plug dry.

Installation

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
The unit can be placed submerged or dry.
Always place the unit below water level.
Place the unit horizontally on the ground ensuring its stable position.
Connect the unit
Push the hose clip and the union nut over the hose. Fit the hose on the stepped hose adapter or hose connector and
secure with the hose clip.
Fit the stepped hose adapter or hose connector on the second inlet (1) or pump outlet (2) and hand-tighten the union
nut.
Submerged installation (A)
Operation with the pre-filter fitted. Push the pre-filter over the suction unit and fasten the filter using the bayonet clo-
sure. Place the unit in the water at the desired position. Ensure that the unit is fully submerged. Maximum installation
depth:4 metres.
Dry installation (B)
Bolt the suction unit on and turn the priming opening to an optimum position for priming and connecting the suction
hose. Connect the suction hose to the suction unit. Always position the unit below the water line to prevent dry running
and the intake of air when switching on and operating the unit. Risk of damage!
Never connect the unit to a water line.
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
18934-12H_GA_USP Classic 200_fin7 7
- GB -
18.12.2012 10:57:10
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis