6. Specifications

Model
Function
Power supply
Capacity
Input
Indoor unit
Airflow (Lo-Hi)
Ext. static
Fan
pressure
Noise level (Lo-Hi)
Weight
Outdoor unit
Noise level (Lo-Hi)
Refrigerant R410A
Weight
Notes: 1. Rating conditions (cooling) Indoor : 27°C DB, 19°C WB
2. Rating conditions (heating) Indoor : 20°C DB
3. Specifications subject to change without notice.
Guaranteed operating range
Upper limit
32°C DB, 23°C WB
Cooling
Lower limit
21°C DB, 15°C WB
Upper limit
Heating
Lower limit
Units should be installed by licensed electric contractor accordingly to local code requirement.
SEZ-KA35VA
Cooling
kW
3.5
BTU/h
11,900
kW
1.06
SEZ-KA35VA
CMM
10-13
Std. : 30 (3)
Pa (mmAq)
Max. : 50 (5)
dB (A)
30-35
kg
33.5
SUZ-KA35VA
dB (A)
48
kg
1.05
kg
35
Outdoor
Indoor
KA35
46°C DB, – 43°C DB, –
-10°C DB, –
27°C DB, –
24°C DB, 18°C WB
20°C DB, –
-10°C DB, -11°C WB
SEZ-KA50VA
Heating
Cooling
~/N, 230V, 50Hz
4.0
5.0
13,600
17,100
1.10
1.78
SEZ-KA50VA
12-17
Std. : 30 (3)
Max. : 50 (5)
31-39
33.5
SUZ-KA50VA
55
1.6
53
Outdoor : 35°C DB
Outdoor : 7°C DB, 6°C WB
KA50, KA60
SEZ-KA60VA
Heating
Cooling
5.9
5.5
20,100
18,800
1.84
1.96
SEZ-KA60VA
12-20
Std. : 30 (3)
Max. : 50 (5)
32-43
33.5
SUZ-KA60VA
55
1.8
53
Heating
6.9
23,500
2.45
15