AVENTICS | AS1 / AS2 / AS3 / AS5 | R412013438–BAL–001–AD | English
System is operating under pressure!
Incorrect installation may damage the maintenance
unit/apparatus and cause serious injury.
O Before commissioning, check that all connections,
ports and maintenance equipment have been
correctly installed.
Mount fastening elements W01 – W05
O Please heed figures
Mount pressure sensor
On the AS5 series pressure sensors can only
be flange-mounted.
2
Flange mounting
1. Remove the blanking screw (a).
2. Insert the molded seal (b) in the seal channel (c)
of the air connection
3. Place the pressure sensor (d) on the flange and
screw it tight.
3
Pipe connection (for AS1/2/3)
1. Remove the blanking screw (a).
2. Close the double nipple (f) with the seals (e1+e2)
and screw the double nipple (f) into the distributor.
Note: The double nipple (f) must be ordered separately,
seals (e1+e2) are included with the double nipple.
3. Screw the pressure sensor (d) onto the
double nipple (f).
Mount accessory components
4
Pipe connection (for AS2 + AS3)
1. Remove the blanking screw (a).
2. Insert the flat gasket (h) in the seal channel (c)
of the air connection.
3. Screw in the accessory components (i) such as push-in
fittings, connection pieces, multiple adapters.
CAUTION
W01
W05
.
6

Service and Repairs

Cleaning and Servicing
W
Close all openings with suitable safety devices so
that no cleaning agent can enter into the system.
W
Never use solvents or aggressive detergents.
Only clean the product using a slightly damp cloth.
Only use water and, if necessary, a mild detergent.
W
Do not use high-pressure cleaners for cleaning.
W
Do not use compressed air for cleaning (blowing off)
the maintenance unit or equipment.
7
Decommissioning,
Disassembly, Replacement
Danger of injury in case of disassembly
or replacement under pressure or voltage
Disassembling or replacement when under pressure
or electrical voltage may lead to injuries and damage
to the product or system components.
O Make sure that the relevant system part is not under
voltage or pressure before you disassemble the
product or replace parts.
O Protect the system against being switched on.
8
Disposal
Dispose of the product and condensate in accordance
with the national regulations in your country.