Assembly location
The smoke detector must be mounted
on the ceiling with a minimum distance
of 66 cm from the nearest corner or wall.
The smoke detector must be positioned
at least 30 cm from any junction box
and at least 150 cm from fluorescent
lamps.
Install at least two smoke detectors,
one per floor and (for additional safety) one in each room.
Do not install the smoke detectors in any area susceptible to draughts
(e.g. near air–conditioners or ventilators).
Do not install the detectors in rooms with high humidity (shower rooms, baths,
kitchens or laundry rooms), rooms with large temperature fluctuations (over 40°C
or under –5°C) or where the detectors can be contaminated by vehicle exhaust
gases, dust and dirt (garage, furnace room, etc.) → in these cases use a heat detector.
Do not install the detector in the top of a roof, because clear air can collect there in
the event of fire.
Install smoke detectors along the escape routes for additional safety.
Ensure that the smoke detectors are easily accessible for testing and repair purposes.
m-RMF
Assemble smoke
detectors in the
middle of room
-16-
66 cm
Never in the
dead corner