12. Technical data

Order no.:
Type:
If not otherwise stated, all data in the complete temperature range
refer to the reference target to EN 60947-5-2 (FE 360 = steel) 45 x
45 x 1 mm.
Electrical design:
Operating voltage:
Current consumption:
Short-circuit protection:
Enable zone:
Safe switching off distance:
Switching frequency:
Voltage drop:
Switching status indication:
Operating mode:
Operating temperature:
Relative humidity:
Height above sea level:
Protection:
Housing materials:
Connection:
2
1
3
4
View on pin side
20
GM503S
GIMC-4030-US
DC
18...30 V (incl. 5% residual ripple)
< 15 mA
yes
10...15 mm
30 mm
min. 0.2 Hz
< 2.5 V
intermittent operation
-25...70°C
< 95%
max. 2000 m
IP 67
PPE, diecast zinc
M12 connector, gold-plated contacts
1
L+
(BN)
2
TE
(WH)
3
L
(BU)
4
A
(BK)
+24 V
G1500x
OUT
G1500x
or
oder
GND
SPS
plc
IN

Werbung