In order to adjust the sensor type, proceed as follows:
Î Select the desired sensor by pressing buttons  and , and confirm with but-
ton .
Î Select the menu item Type and confirm by pressing button .
Î Select the right sensor type and confirm by pressing button .
If the sensor type Impulse has been selected, the impulse rate can be adjusted. In
order to adjust the impulse rate, proceed as follows:
Î Select the desired sensor by pressing buttons  and , and confirm with but-
ton .
Î In the corresponding sensor menu, select the menu item Vol./Imp.
Î Adjust the desired value by pressing buttons  and , and confirm with but-
ton .
Sensor offset
In order to adjust an offset for the sensor inputs S1 ... S3, proceed as follows:
Î Select the desired sensor by pressing buttons  and , and confirm with but-
ton .
Î Select the menu item Offset and confirm by pressing button .
Î Adjust the desired value by pressing buttons  and , and confirm with but-
ton .
If the current loop interface is used, the type can be adjusted. The following types
are available:
• None
• 0 - 20 mA
• 4 - 20 mA
• Si-420TC
In order to adjust the type, proceed as follows:
Î Select the menu item Current loop by pressing buttons  and , and confirm
with button .
Î Select the Type sub-menu.
Î Select the right type and confirm by pressing button .
If an error occurs in a sensor connection, the operating control LED flashes and
the message Input (1 ... 4) no signal appears on the display.
30
5.5.6 Logging
In the Logging sub-menu, the following adjustments can be made:
• Interval
• Logging type
• SD card (only if an SD card has been inserted into the SD card slot)
When Interval has been selected, the logging interval can be adjusted. In order to
adjust the interval, proceed as follows:
Î Select the number of minutes by pressing buttons  and , and confirm with
button .
Î Select the number of seconds by pressing buttons  and , and confirm with
button .
In the menu item Log. type, one of the following logging types can be selected:
• linear
• cyclic
When linear is adjusted in the Logging type adjustment channel, data logging will
stop if the capacity limit is reached. If cyclic is adjusted, the oldest data logged into
the internal memory will be overwritten as soon as the capacity limit is reached.
When Log. type has been selected, the logging type can be adjusted. In order to
adjust the logging type, proceed as follows:
Î Select the desired logging type by pressing buttons  and , and confirm with
button .
In the menu item SD card, the following adjustments can be made:
• Backup
• Format card
• Update
When Backup has been activated, the data logged over the previous day will be
copied onto the SD card at midnight (00:00), using the VBus
remain in the internal memory as well.
When Format card has been selected, the SD card will be formatted. In order to
format the SD card, proceed as follows:
Î Select the menu item Format card by pressing buttons  and , and confirm
with button .
Î To format the card, select Yes and confirm by pressing button .
During the formatting process, the message Please wait... is indicated. When for-
matting has been completed, the message Successful! appears. Press any key to
leave the menu item.