4. Then you switch to the item where you can set the CO
procedure as described in number 2, you can set this value by pressing the START/STOP
and SET buttons.
5. When the desired value is shown in the display, again press the SET and FUNCTION
buttons simultaneously until the display switches back to the starting point.
The electricity price and CO
even when the SEM 16+ / SEM 16+ USB is unplugged from the power supply. The next
time you operate the unit the programmed values will be used again.
You can change the electricity price and the CO
!!!
Note: The 'costs' symbol is the currency-neutral symbol for the currency used. In
Germany and many European countries it represents '€' (e.g.: 0.150 costs/kWh = 0.15€/kWh).
!!!
Tip:Your power supply company can provide you with the applicable price per kWh.
!!!
Tip:Your power supply company can provide you with the applicable emissions factors
for the CO
calculation.
2

SET LOADING POINT INTERVAL TIME (SEM 16+ USB ONLY)

The continuously records the course of the power consumption, idle power measurement,
the current and the voltage during the measurement. It is then possible with the Home
Energy Monitor software to display the characteristic line for the power consumption,the
idle power measurement, the current and the voltage for the measurement time period. It is
determined with the loading point interval time period at which time gaps for the values are
saved. It is possible to select between 1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30 and 60 minutes. If a
short time period is selected a more detailed characteristic line can then be later displayed,
which means even short time period loading changes will be exactly protocolled. If a large
time period gap is selected the characteristic line is not as detailed but however a longer
time period can be recorded. The storage capacity for the SEM16 USB is approximately
14,000 storage points.
Example:
• A loading course interval of 1 minute is set. That means that a loading course of 14,000
minutes or 9 days, 17 hour and 20 minutes can be recorded.
• A loading course interval of 15 minutes is set. That means a loading course of 14,000 x 15
minutes which = 210,000 minutes or 145 days and 20 hours can be recorded.
Please take note that the read-out of the complete load course storage can take up to 30
minutes. For this reason it could be sensible to select a loading course interval so that the
storage facility is only partially utilized.
NZR – Ihr Partner für Energiemessung
20
emissions factor you have saved in the unit are retained
2
value at any time.
2
value. Following the same
2