HOW TO SET A DIFFERENT MEASURING PERIODE

To achieve the most exact measuring results possible, the measurement must be conducted
over a defined period of time. In the standby energy monitor a measuring time (0, 1 day, 7
days or 30 days) can be set; after this time, the measuring stops automatically. Measuring
starts automatically as soon as an appliance is plugged into the unit. Measuring can also be
started and stopped manually.
The measuring period depends on the appliances to be measured: For an appliance that is
continuously switched on 365 days a year and has a constant energy consumption (e.g. a
clock), a short measuring period is sufficient.
The projected energy costs for one year are displayed immediately. Appliances with
fluctuating energy consumption have to be monitored over a longer period. For an
appliance with relatively constant energy consumption from day to day (e.g. a refrigerator),
a measuring period of one day can already provide very accurate results. Appliances with
constant energy consumption over a period of one week (e.g. a television) can be measured
effectively over a measuring period of 7 days. Appliances that are operated at regular
intervals (e.g. a washing machine or printer) should be measured over an extended period
(30 days, manual start/stop). In general, the longer the measuring period, the more accurate
the cost estimate will be.
1) Press the START/STOP and SET buttons simultaneously until "REC TIME" "1d"
(d = day) appears on the display.
2) Press the START/STOP button to switch between 7, 30 or 0 days and back to 1 day.
3) If you select a measuring period of "0 days" you can automatically start the
measurement by pressing the START/STOP button and stop the measurement by
again pressing the START/STOP button.
Press the START/STOP and SET buttons simultaneously for 3 seconds again to save
the selected measuring period and exit the menu. The configured measuring
period is now stored in the unit and will be retained even after resetting the
measured values.
NZR – Ihr Partner für Energiemessung
18
Setting for measuring period of one day. (1 d = 1 day)
Setting for measuring period of one week. (7 d = 7 days)
Setting for measuring period of one month. (30 d = 30 days)
Setting for user-defined measuring period.
(0 d = start and end of measuring period can be selected freely)