5) Press SET to switch between the following information on the display:
The measuring times are first shown in minutes / seconds, then in hours / minutes
and finally in days / hours.
SEM 16+ USB only
6) At the end of the measuring time, measuring is ended automatically if the duration
of the measuring period has not been set differently (see Measuring period). You
can continue to switch between the various displays, as described in numbers 4 and 5.
7) After measuring has stopped and the measurements have been analyzed, the
results can be reset to '0'. To do this, you have to open either menu item 2) Energy
costs or 3) Energy consumption. Now press the START/STOP button for 3 seconds
to reset all values to '0' with the exception of the setting for the electricity price. The
measuring result can also be reset to '0' while a measurement is in progress.
Now it is possible to carry out a new measurement.

HOW TO RESET YOUR MEASURING RESULTS

All values measured by the SEM 16+ / SEM 16+ USB can be reset to '0' only in the menu
items Energy consumption and Energy costs. Press the START/STOP button for about
3 seconds to reset all values, such as the energy consumption, energy costs, CO2
consumption and the power measurements, minimum and maximum power. Then you can
start a new measurement.
NZR – Ihr Partner für Energiemessung
REC TIME
Total time since measuring started
ON TIME
The time in which the connected appliance has
consumed power. For appliances that automatically
switch on and off, such as a refrigerator or
iron, this display shows how long the appliance was
actually active. An appliance is considered switched
on if it has a power draw of 1 watt or more.
TIME
The time is required for recording the
characteristic line (load process) for the power
consumption, the current and the voltage and can
only be made available over the PC software.