4.

Filter/pump installation

The filter with pump (Fig.1 ) are employed in filtering above ground and in-ground pools, where
careful and expert water cleaning is required. The filter/pump is positioned at least 3.5 m from the
edge of the pool. The water temperature must not exceed 35° or drop under minus 4 º C.
Beware!
Disconnect the plug before starting to do any work.
Before installing the filter pump unit, identify the position in which it is to be installed, as
once it has been filled up with sand, the filter is hard to move due to its weight.
Priming
The hoses should be primed so that the filter plus the hoses are totally filled with water. Lift hoses
up over filter system to help water to run to the pump then lower the hoses again. This procedure
must be done until the filter pump and the hoses are filled with water and the pump itself begins to
suck water through. By doing this, the pump creates a vacuum so it is only needed to be done one
time, (if the hoses are not removed in the meantime).
Beware!
Always place the filter system under the water surface in the pool, so that the water can
flow naturally towards the pump. Is it used with an in-ground pool, you have to place
the filter system correspondingly lower into a shaft/pit in the ground, so the water can
flow by itself into the pump. Be sure that the shaft/pit stays dry. There should be an out-
let/drain to lead the water out of the shaft/pit.
4.1
Filter installation
Insert the tube with the manifold (6) in the tank (Fig. 3) and screw the small sand guard filters (7)
to the manifold (Fig. 4). Place the completed manifold in the middle of the tank and fill ¼ with
water to stabilize the tank and make sure that sand grains sets in the filters during filling.
Fig. 3
Side 36
Fig. 4
MV-1030-1050-03-2019 . © All rights reserved Swim & Fun Scandinavia ApS
GB

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Classic 40010501030

Inhaltsverzeichnis