2.5 Commissioning

First switch ON the mains power. The controller
passes through an initialisation phase during
which the operating indicator lamp flashes red
and green.
You need to scroll through a commissioning
menu if the controller is started for the first
time or following a reset.
Operation of the commissioning menu:
Press
.
SET
Symbol
flashes.
SET
f Press key 1 or 2 to select the value you
require.
f Press
to confirm the selected value.
SET
Symbol
will again be displayed perman-
SET
ently.
f Press key 1 or 2 to call up the next or previ-
ous setting channel.
The commissioning menu contains the follo-
wing setting channels:
SPR :
Language setting
Setting range: dE, En
Factory setting: dE
EINH: Selection of
temperature unit
Setting range: °F, °C
Factory setting: °C
S MX: Maximum cylinder
temperature
Setting range: 4 ... 95 °C
Factory setting: 60 °C
nMN: Speed control
Setting range: 30 ... 100
Factory setting: 30
Confirmation prompt
.
22
The language for the menus is set in this channel.
• dE : Deutsch [German]
• En : English
With this parameter you determine the unit for displaying temperatures and
$(-'
temperature differentials.
SET
°"
Where the set maximum temperature is exceeded, further heating up of the
2 ,7
cylinder is prevented and thus damaging overheating avoided. Where the
SET

maximum cylinder temperature is exceeded, the display shows
°C
Note: The controller is equipped with a cylinder safety stop facility that prevents
further heating at 95 °C (system cooling function).
Setting channel nMN default a relative minimum speed for connected pumps for
output R1.
CAUTION:
When using consumers without variable speed control (e.g. valves), set the value
to 100% to disable the variable speed control.
After you have set the last parameter in the commissioning menu, the controller
.*
will prompt you for confirmation.
SET
Press key 3 to confirm your settings.
The controller is now ready to operate. The settings made in the commissioning
menu can be changed any time after the commissioning in the relevant parame-
ter.
.