Herunterladen Inhalt Inhalt Diese Seite drucken

Setting To Work - Connection To The Power Supply; Extensions - Nilfisk cfm WSS 100 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33
WSS100 - WST100
Setting to work - connection to the power
supply
Make sure that the vacuum cleaner is in perfect
condition before starting work.
Before plugging the vacuum cleaner into the
electrical mains, make sure that the voltage rating
indicated on the data plate corresponds to that of
the electrical mains.
Plug the vacuum cleaner into a socket with a
correctly installed ground contact/connection.
Make sure that the vacuum cleaner is off.
The plugs and connectors of the connection
cables must be protected against splashed water.
Make sure that connections to the electrical
mains and plug are correct.
Use the vacuum cleaners only when the cables
that connect to the electrical mains are in perfect
condition (damaged cables could lead to electric
shocks!).
Regularly check that the electric cable does not
show signs of damage, excessive wear, cracks or
ageing.
When the vacuum cleaner is operating:
Do not crush, pull, damage or tread on the cable
that connects to the electrical mains.
Only disconnect the cable from the electrical
mains by removing the plug (do not pull the
cable).
Only replace the electric power cable with one of
the same type as the original (H05 VV-F); the same
rule applies if an extension is used.
The cable must be replaced by the manufacturer's
Service Centre staff or by equivalent qualified
personnel.
GB
09/2014
WARNING!
WARNING!

Extensions

If an extension is used, make sure it is fit for the power draw
and protection degree of the vacuum cleaner.
Minimum section of extension cables:
Maximum length = 20 m
Cable = H05 VV-F
Max power (kW)
Minimum section (mm
)
2
WARNING!
Sockets, plugs, connectors and installation of the
extension cable must maintain the IP protection
degree of the vacuum cleaner, as indicated on the data
plate.
WARNING!
The vacuum cleaner's power socket must be protected
by a differential circuit-breaker with surge current
limitation, that shuts off the power supply when the
current discharged to the ground exceeds 30 mA for
30 msec. or an equivalent protection circuit.
WARNING!
Never spray water on the vacuum cleaner: this could
be dangerous for persons and could short circuit
the power supply. Consult the latest edition of the
European Union Directives, the Laws in the country of
use and the current standards in force (UNI - CEI - EN),
in particular the European standard EN60335-2-69.
4
3
5
15
22
2.5
4
10
16

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Wst 100

Inhaltsverzeichnis