Cleaning the containers

Before proceeding with these operations, turn off the
vacuum cleaner and remove the plug from the power
socket.

Shaving container (optional)

Clean the container after each emptying (see "Emptying
the shaving container" paragraph).
Check that the holes are free of dirt; clean them if
necessary.

Liquid container

1
Float and relative support
2
Shaving container (optional)
3
Container closing band
4
Liquid exhaust valve
Empty the liquid container (see "Emptying the containers"
paragraph).
Open the liquid container closing band (3).
Lift the motor head.
Remove the float and its support (1) or the shaving
container (2) (optional).
Wash the container with water to remove deposits.
Open the exhaust valve (4) to empty the container.
Close the exhaust valve (4).
Place the float and its support or the shaving container (if
applicable) back into position.
N.B. Make sure the float support is correctly
positioned (fig. 9).
Lock the motor head by using the liquid container closing
band (3).
GB
09/2014
WARNING!
Figure 9
Cleaning or replacement of the vapour
filters
1
Filters
2
Baffle plate
3
Filter box
Remove the safety screw (4) and open the motor head
clamp (5).
Lift the motor head.
Remove the filter box (3) by unscrewing the fixing
screws.
Remove the filters (1) and the baffle plate (2), then clean
the filters with water or replace them if necessary.
Reinstall the filters (1) and the baffle plate (2) making
sure they are correctly positioned.
Install the filter box and secure it by screwing the fixing
screws.
Reinstall the motor head and close the container with the
appropriate closing band, then put the safety screw in
place (4).

Tightness inspection

1
Vacuum hose
2
Liquid level indicator tube
Hoses check
Make sure that the suction connecting hose (1) and the
level hose (2) are in a good condition and correctly fixed.
If the hose is damaged, broken or badly connected to the
unions, it must be replaced.
1
Gasket
2
Liquid container
3
Motor head
Motor head tightness check
Replace the seal (1) between the container (2) and the
motor head (3) if it is torn, cut, etc.