Herunterladen Inhalt Inhalt Diese Seite drucken

Outline Diagram - Nibe PCS 44 Installateurhandbuch

Passive kühlung
Vorschau ausblenden Andere Handbücher für PCS 44:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB

Outline diagram

Explanation
EB100
Heat pump system
BT1
Temperature sensor, outdoor
BT6
Temperature sensor, hot water
BT7
Temperature sensor, hot water, display
EB100
Heat pump
HQ1
Particle filter
EQ1
Cooling system
AA25
Unit box with accessory board (AA5)
BT64
Flow temperature sensor, cooling
BT65
Return line sensor, cooling
EP13
Fan convectors
GP13
Circulation pump, cooling
QN18
Mixing valve, cooling
RM5
Non-return valve
Designations in component locations according to standard IEC 81346-1 and 81346-2.
Outline diagram F1145/F1155 with PCS 44
-EQ1
-AA25
-EP13
-BT65
-BT64
-GP13
14
-QM12
-CM2
-QM42
-XL15
-FL3
-QM34
A
-QN18
AB
B
-RM5
-EP12
Miscel-
laneous
CM1
Expansion vessel, heating medium side
CM2
Level vessel
CP10
Accumulator tank
EP12
Ground-source heating/Ground collector
FL2
Safety valve, heating medium
FL3
Safety valve, brine
QM12
Filler valve, brine
QM31
Shut-off valve, heating medium flow
QM32
Shut off valve, heating medium return
QM34
Shut off valve, brine flow
QM42
Shut-off valve
XL15
Filling set, brine
-EB100-BT1
-QM31
-EB100
-EB100
-BT7
-FL2
-CP10
-CM1
-HQ1
-QM32
-EB100-BT6
PCS 44

Werbung

Inhaltsverzeichnis
loading