Mounting
Standard bus hands-free
telephone with colour monitor
for Siedle in-home bus
Functions:
• Calling, hands-free/simplex
communication, video, door release
and storey call
• Speech/control button
• Door opener and light button
• Internal speech communication
• Muting button for call tone
• 10 call tone melodies
• Call and speech volume adjustable
in 5 steps
• Potential-free contact for
additional signal device
• Colour monitor 6.3 cm (2.5")
• Monitor button for current picture
• Brightness and colour regulation
• Direct door dialling (video and
sound)
Electrical voltage
Mounting, installation and
servicing work on electrical
devices may only be performed
by a suitably qualified electrician.
Electrostatic charging
As a result of electrostatic charging,
direct contact with the circuit board
can result in destruction of the
device. Direct contact with the
circuit board must therefore be
avoided.
Scope of supply
• BFSV 850-... (base plate and
housing with monitor unit)
• Operating instructions for the end
user
• This product information
Mounting
Strip the cable back to appr. 80 mm.
1 Recommended mounting height
appr. 1.50 m/4.9 ft to centre device.
4
2 Open the device from the back by
pressing in the locking lever.
3a When mounting directly on the
wall, fasten the base plate using 4
screws, paying attention that the
plate is the right way up (top
marking).
3b When mounting on a switch box,
use the screw openings in the centre
of the device, paying attention that
the plate is the right way up (top
marking).
4 Install in accordance with the
AS diagram. The cores of the
installation cable must be stored
inside the free installation space in
the base plate.
5 Hook the top of the housing into
the base plate and close by exerting
a slight pressure.
6 Depending on the installation
environment, it may be necessary to
change the microphone sensitivity of
the BFSV 850-... in order to permit
clear speech transmission.
Control range –6 dB to +4 dB.
Dismantling
7 To remove the housing, press the
lock upwards using a flat blade
screwdriver. The circuit board
remains in the housing
superstructure
Terminal assignment
TaM/TbM = In-home bus input
TaM/TbM = In-home bus
throughput
ERT/ETb
= Storey call button
+M/-M
= Additional supply
20–30 V V DC
S1/S1
= Potential-free contact
for extra doorbell
15 V AC, 30 V DC, 1A
Commissioning
Installation, commissioning and
programming procedures are
described in the system manual
(enclosed with Bus Video Line
Rectifier BVNG 650-...).
Accessories for BFSV 850-...
• ZTSV 850-... for conversion from a
wall appliance to a desk appliance.
Specifications
• Supply via in-home bus
• Ring tone volume: max. 83 dB (A)
• Colour monitor 6.3 cm (2.5")
• Current consumption on supply via
+M/-M max. 300 mA
• Potential-free contact S1/S1 max.
15 V AC/30 V DC, 1 A
Switching time 0.4 secs. - 19 mins.
• Dimensions W x H x D
90 x 261 x 27 mm