Problem
Cause
Melting point of glue
stick is too high
Adhesive flows
Glue stick diameter
backwards in the
too small.
glue pen.
"Threads" de-
Feed is still activated
velop as the glue
when the application
pen is removed
of adhesive is fin-
from the bonding
ished.
location after ap-
Discharge nozzle has
plying adhesive.
not been wiped off.

Maintenance and Servicing

Maintenance and cleaning

Warning! Switch the glue pen off before commencing
u
maintenance and cleaning work.
Keep the glue pen clean to ensure good, safe operation.
u
After the adhesive has hardened, you can remove it with a
blunt object. Do not use solvents when cleaning. If necessary,
the bonding locations can be unstuck again by applying heat.
Take particular care to keep the slider (5) and its guide clean.
Remove adhesive residue with a blunt object after it has
cooled.
Do not remove an inserted glue stick (3) out of the back of the
glue pen.
After-sales service and advice on using products
Our after-sales service can answer questions concerning
product maintenance and repair, as well as spare parts. You
can find exploded drawings and information on spare parts at:
www.bosch-pt.com
The Bosch product use advice team will be happy to help you
with any questions about our products and their accessories.
In all correspondence and spare parts orders, please always
include the 10‑digit article number given on the type plate of
the product.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange
the collection of a product in need of servicing or repair.
Tel. Service: (0344) 7360109
E-Mail: boschservicecentre@bosch.com
Ireland
Origo Ltd.
Unit 23 Magna Drive
Magna Business Park
Bosch Power Tools
English | 17
Corrective meas-
ure
Use recommended
original glue sticks.
Use recommended
original glue sticks.
Stop the feed just
before finishing ap-
plying adhesive.
After finishing ap-
plying adhesive
wipe off the nozzle
on the workpiece.