Shutting down
8.1 Emptying and cleaning >>
Solvents
Gasoline
Oil
tion to the safety instructions in this manual. Observe applicable laws and the specifications
of the agent manufacturers when disposing of residual quantities.
Activate the pressure relief valve – red button – until the device is depressurised. The pressure
relief valve may only be activated when the device is in an upright position.
8.2 Maintenance >>
NOTE!
Observe the national regulations concerning occupational safety which apply to the place of
operation as well as the applicable national regulations for operations. An expert inspection must
be performed – ideally by the maintenance service of the manufacturer – to establish whether
hazard-free operation remains possible. This should be performed in the event of defects that
may impair safety in particular, and must be performed at least every 5 years in any case.
Only use original GLORIA spare parts for repairs.
(see GLORIA spare parts shop https://shop.gloriagarten.de).
Repairs must only be carried out by a GLORIA service point.
It is forbidden to perform repair work on the container (such as welding and soldering).
Further accessories can be found at www.gloriagarten.de
8.3 Storage >>
CAUTION
device and the spraying pesticides. You must therefore store the device and the spraying
agents out of the reach of children.
Empty and clean the device as in Chapter 8.1.
9
Problems with the device
Fault
Device is leaking at the
screw connection
Spray pattern of
nozzle not OK
Pump does not build
up any pressure
figures
CAUTION
Danger to health due to escaping spraying agents! Pay atten-
figures
29
–
31
figure
32
You may be exposed to hazards that could injure you when handling the
Cause
Hose loose
Nozzle partially blocked
Filter in quick closure valve
contaminated
O-ring on piston is
worn
–
23
28
Remedy
Tighten coupling nut
and carry out pressure
test with water
Clean filter or nozzle
Replace O-ring
22