INSTRUCTION MANUAL
Machine Type:
Pneumatic tool with 1/2" sq. shank for use with chisel and various
1/2" sq. shank accessories, needles - No other use is permitted.
Air Supply Requirements
1. Supply tool with 90 psig (6.3 bar) of clean, dry air. Higher
pressure drastically reduces tool life.
2. Connect tool to air line using pipe, hose and fitting sizes shown
in the diagram below.
3/8" (10mm)
3/8" (10mm)
Lubrication
Use an air line lubricator with SAE #10 oil, adjusted to two drops
per minute. If an air line lubricator cannot be used, add air motor
oil to the inlet once a day.

Operation

For Needle Scaler
1. Push in the front assembly and twist to the open slot, then pull
needle assembly out of housing.
2. Remove worn needles from holder and replace with new
needles, making sure the needle heads fit into the countersunk
holes in needle holder.
3. Slide needles through spring and front nosepiece. Check that
driver is not damaged and placed inside housing correctly.
4. Lubricate entire needle assembly with a light coating of oil.
Reassemble by sliding assembly into the housing, line up slot,
then push in and twist to lock in place.
For Chisel Scaler
1 To insert chisel, press loop on retainer aside, push chisel into
cylinder and release loop.
2. Place cutting edge of chisel against workpiece, depress trigger.
Caution: Do not operate tool without chisel in cylinder, or
allow the chisel to be driven out of cylinder. Internal damage
will result if piston is allowed to strike cylinder wall.

Maintenance

1. Disassemble and inspect tool every three months if the tool
is used every day. Replace damaged or worn parts.
2. High wear parts are underlined in the parts list.
3. To keep downtime to a minimum, the following service kits
are recommended:
Tune-Up Kit: 2050506933
Original Instructions
Copyright 2010, Chicago Pneumatic Tool Co. LLC
All rights reserved. Any unauthorized use or copying of the
contents or part thereof is prohibited. This applies in particular to
trademarks, model denominations, part numbers and drawings.
Use only authorized parts. Any damage or malfunction caused
by the use of unauthorized parts is not covered by Warranty or
Product Liability.
1/2" (12 mm)
CA048362 (1/2")
3/8" (10mm)
3/8" (10mm)
3/8" (10mm)
CA048360 (1/2")
CA048361 (1/2")
Technical Data
1/2 in shank
Air comsumption: 15 cfm (7.4 l/s)
Air Pressure 90 psi (6.3 bar)
Bore and Stroke: 1 x 1,1 in. (25x28 mm)
BPM: 4800
Noise & Vibration Declaration*
Sound pressure level
88 dB(A)
uncertainty 3 dB(A), in accordance with EN ISO 15744. For sound
power, add 11 dB(A).
Vibration value
a=11.4 m/s² , uncertainty k=3.4 m/s² re. ISO 28927-9
Declaration of noise and vibration emission
All values are current as of the date of this publication. For the
latest information please visit cp.com.
These declared values were obtained by laboratory type testing
in accordance with the stated standards and are suitable for
comparison with the declared values of other tools tested in
accordance with the same standards. These declared values are
not adequate for use in risk assessments and values measured in
individual work places may be higher. The actual exposure values
and risk of harm experienced by an individual user are unique
and depend upon the way the user works, the workpiece and
the workstation design, as well upon the exposure time and the
physical condition of the user.
We, Chicago Pneumatic, cannot be held liable for the
consequences of using the declared values, instead of values
reflecting the actual exposure, in an individual risk assessment in a
work place situation over which we have no control.
This tool may cause hand-arm vibration syndrome if its use is
not adequately managed. An EU guide to managing hand-arm
vibration can be found at http://www.humanvibration.com/EU/
VIBGUIDE.htm
We recommend a programme of health surveillance to detect early
symptoms which may relate to noise or vibration exposure, so that
management procedures can be modified to help prevent future
impairment.
MANUFACTURER'S LIMITED WARRANTY
Limited Warranty:
The "Products" of the Chicago Pneumatic Tool
Co. LLC ("CP") are warranted to be free from defects in material and
workmanship for one year from the date of purchase. This Warranty
applies only to Products purchased new from CP or its authorized dealers.
Of course, this Warranty does not apply to products which have been
abused, misused, modified, or repaired by someone other than CP or its
Authorized Service Representatives. If a CP Product proves defective in
material or workmanship within one year after purchase, return it to any
CP Factory Service Center or Authorized Service Center for CP tools,
transportation prepaid, enclosing your name and address, adequate
proof of date of purchase, and a short description of the defect. CP will,
at its option, repair or replace defective Products free of charge. Repairs
or replacements are warranted as described above for the remainder of
the original warranty period. CP's sole liability and your exclusive remedy
under this Warranty is limited to repair or replacement of the defective
Product. (There Are No Other Warranties Expressed Or Implied And
CP Shall Not Be Liable For Incidental, Consequential, Or Special
Damages, Or Any Other Damages, Costs Or Expenses Excepting
Only The Cost Or Expense Of Repair Or Replacement As Described
Above.)
CP7120
Hammer

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis