Herunterladen Inhalt Inhalt Diese Seite drucken

Auto Dump; Starting - Husqvarna DC 6000 Bedienungsanweisung

Vorschau ausblenden Andere Handbücher für DC 6000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Auto dump

The Auto dump function will automatically open/release
pressure and empty the cyclone in pre set intervals. This
function also significantly improves the cleaning of the
filter.
3 sec
3 min
3 min
Restriction valve
With the restriction valve you can choose to enable/
disable the Auto dump function. It is recommended to run
the machine with the valve open. NOTE! Dust control of
dust under the grinding head is less efficient with the valve
open during the 3 second auto dump/filter purge function.
Run the machine with the valve closed for more efficient
dust control during the 3 second auto dump/filter purge
function.
NOTE! It is important that the dust skirt on the grinder is
in good condition for efficient containment of dust during
operation.
STARTING AND STOPPING
3 sec
3 sec
3 sec
3 min
3 min

Starting

Position the vacuum in the working area.
Ensure the machine is raised.
Ensure the dust bag holder is secured in its mountings
on the containers. Ensure the dust bag is secured
around the containers and is gathered with cable ties
at the bottom.
Check that the suction hose is secured to the
connector.
Push the green button (1).
A white lamp is lit up. Wait around 30 seconds until
the compressor has reached the correct pressure.
The machine has power and is in stand-by mode.
Turn the switch to the ON position (I).
English
11

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis