11. Trouble Shooting
Having trouble?
Noise is louder than specifi cations.
Nothing appears in the wireless remote controller display, the display is
faint, or signals are not received by the indoor unit unless the remote con-
troller is close.
The operation lamp near the receiver for the wireless remote controller on
the indoor unit is blinking.
12. Specifi cations
Model
Power source(voltage <V>/Frequency<Hz>)
Rated Input(Indoor Only)
Rated Current(Indoor only)
HEATER
Dimension(Height)
Dimension(Width)
Dimension(Depth)
Fan airfl ow rate(Low-Middle2-Middle1-High)
Noise level(Low -Middle2-Middle1-High) <dB>
Net weight
*1 The fi gure in ( ) indicates GRILL`s.
20
PLA-RP35BA
PLA-RP50BA
<kW>
0.03
<A>
0.22
<kW>
-
<mm>
<mm>
<mm>
11-12-13-15
12-14-16-18
<m
3
/min>
27-28-29-31
28-29-31-32
<kg>
22(6)
Here is the solution. (Unit is operating normally.)
The indoor operation sound level is affected by the acoustics of the par-
ticular room as shown in the following table and will be higher than the
noise specifi cation, which was measured in anechoic room.
High sound
absorbing rooms
Location
examples
Noise levels
The batteries are low.
Replace the batteries and press the Reset button.
If nothing appears even after the batteries are replaced, make sure that
the batteries are installed in the correct directions (+, –).
The self diagnosis function has operated to protect the air conditioner.
Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be sure
to provide the dealer with the model name.
PLA-RP60BA
PLA-RP71BA PLA-RP100BA PLA-RP125BA PLA-RP140BA
~/N 230/50
0.05
0.05
0.07
0.36
0.36
0.51
-
-
258(35)
840(950)
840(950)
12-14-16-18
14-16-18-21
28-29-31-32
28-30-32-34
23(6)
Normal rooms
Broadcasting
Reception room,
studio, music
hotel lobby, etc.
room, etc.
3 to 7 dB
6 to 10 dB
0.14
0.15
0.94
1.00
-
-
-
298(35)
20-23-26-30
22-25-28-31
32-34-37-40
34-36-39-41
25(6)
Low sound
absorbing rooms
Offi ce, hotel
room
9 to 13 dB
0.16
1.07
-
24-26-29-32
36-39-42-44
27(6)

Quicklinks ausblenden: