Trumavent-fan
for warm air
distribution
and ventilation
Installation
instructions
Installation and repairs are
only to be carried out by
an expert! Read the instal-
lation instructions carefully
prior to starting work.
Do not use this fan
for the Truma S 55 T
heater. When installing the
Truma vent fan the exhaust
duct routing of the heater is
not to be altered or damaged
(routing ascending, if neces-
sary using exhaust duct
support)!
6
Installation of the
fan on the heater
installation box as
from date of
manufacture 05/96
Fig. A: Remove pre-perfora-
ted cover on the back of the
installation box. Screw in or
release screws (1) so that the
attachment straps of the fan
can be engaged. Carefully
tighten screws.
Installation of fan on
heater installation
box up to date of
manufacture 05/96
Fig. B: Remove pre-perfo-
rated cover on back of instal-
lation box and remove screw
(2), if necessary. Screw in
screws (3) or release until the
attachment strap of the fan
can be engaged, screw in
screw (5), if necessary.
Align fan at recess (4) to
screw (5). Drill 2 new holes
with 2 mm diameter for the
attachment points (6), when
doing so, make sure that
both metal parts are drilled
through. Screw on fan
with self-tapping screws
3.5 x 22 mm.
Installation of the fan
on the installation box
for two fans
For the heater Trumatic
S 5002 a special installation
box is available for the con-
nection of two fans.
On the right-hand fan turn the
warm air connection fitting
(fig. B: 7) in such a way that
the steep outflow is centered.
For this purpose, before at-
taching to the installation
box, release the screw (8),
turn warm air connection
fitting (7) around and fasten
again with screw (8).
Installation of external
control panel
Fig. C: When selecting the
location, observe the fact
that the control panel (9) is
not to be exposed to direct
heat radiation. The length of
the connecting cable (10) is
1.5 m.
If it is not possible
to install the control
panels flush with the sur-
face, Truma can provide a
surface-mounting frame on
request, as a special accessory
(11 – Part no. 40000-52600).
Drill a hole 55 mm in diam-
eter. Feed the cable through
to the back and secure the
operating unit (9) with four
screws (12). Then fit the
cover frame (13) on and lay
the cable to the fan.
To round off the ap-
pearance of the cover
frame, Truma can provide
side pieces (14) as special
accessories in 8 different
colours (please ask your
dealer).