Installation of the
integrated control
panel (only for fan TEB)
With S 3002 (P, K)-series
heater units (as from date
of manufacture 05/96) and
S 5002-series heater units
(as from date of manufacture
05/98) the control panel can be
flush fitted in heater casing.
Fig. D: Remove cover on the
heater casing. Plug connecting
cable (15) on control panel
(16). Bend back strap (17) on
the heater installation box
and lead through connecting
cable (15). Insert control pan-
el (switch facing the front).
For assembly with the
comfort kit with Airmix,
there is a control panel cable
measuring 1.3 meters in length
(Part no. 40000-47900).
Electrical connection
for Trumavent
TEB 12 V
Technical data:
Power supply: 12 V
Power consumption:
0.3 to 1.0 A
Air flow rate:
up to 135 m
3
/h
(with air duct ÜR dia. 65 mm)
up to 142 m
3
/h
(with air duct dia. 72 mm)
EEC Type Approval:
e1 022603
In Germany, in accord-
ance with Section 22
a StVZO, electric cables,
switching and control panels
for heaters in a vehicle must
be arranged in such a way
that their satisfactory opera-
tion cannot be adversely af-
fected under normal operat-
ing conditions. All cables to
the outside must be splash-
proof at the leadthrough.
When power supplies
are being used, it must
be noted that the output
voltage is between 11 V and
15 V and the alternating
current ripple is < 1.2 Vpp.
Prior to working on
electric components
the appliance must be dis-
connected from the power
supply. Switching off at the
control panel is not sufficient!
Fig. A: Plug on connector
of control panel cable (18).
Connect appliance to fused
vehicle electrical system with
cable 2 x 1.5 mm
2
. Nega-
tive cable to central ground.
When connecting directly to
the battery, fuse the plus and
minus line. Connect with fas-
ton terminals, fully insulated
(motor vehicle flat connector
system 6.3 mm).
Plug connection (K) is only
for the heater Trumatic
S 3002 K. The entire electri-
cal connection of this heater
model must be carried out as
specified in the heater instal-
lation instructions.
If the connections are
interchanged there is
a risk of cables burning. Fur-
thermore, this rules out any
guarantee or liability claim.
The Trumavent fan TEB can
also be operated with 230 V~
by using the Truma voltage
converter SPU (Part no. 40000-
47700). The assembly of the
SPU voltage converter should
be as close to the floor as
possible. It is not possible
to connect further 12 V
appliances to this voltage
converter.
The Truma battery char-
ger NT12/ 3-18 (Part no.
39901-01) is recommended
for connecting multiple 12 V
devices. This charger (with a
charging current of 18 A) is
suitable for charging lead-ac-
id or lead-gel batteries. Other
chargers must only be used
with a 12 V battery as a buff-
er. Mains power supplies and
other power supply equip-
ment must have a controlled
12 V output (AC component
less than 1 Vpp).