6.2

Carrying out surface treatment

Depending on the type and condition of your substrate, pre-cleaning before the plasma
process can improve the overall outcome.
The effect of the treatment depends on the working distance, treatment time, speed
and consistency of movement as well as the material to be treated.
Ensure that the substrate is not thermally damaged due to movement that is too slow or
a working distance that is too low.
Treatment examples can be requested directly from Relyon Plasma GmbH.
6.3

Measures to take after the surface treatment

To achieve an optimal result, it is important that as little time as possible elapses after
the plasma treatment and that the treated surface is not touched or contaminated.
Cleaning the surface AFTER the plasma treatment is not recommended.
Since the workpiece can heat up depending on the type and duration of the plasma
process, it may be necessary to allow the workpiece to cool down first before the next
process step is executed in order to not negatively affect the follow-up process through
the introduction of heat (e.g. certain bonding processes).
Caution – Hot surface!
The workpiece to be treated can become heated up by the plasma process depending on
the process parameters. If necessary, allow the workpiece to cool down before handling it.
7

Operation

Ensure that the fan grille is not covered so that the device can draw in enough ambient
air.
Always hold the device in the middle area where the button and the logo plate are
located and not in the area closer to the tip (see picture).
When mounting the device, follow the advice below concerning electrical conductive
devices.
Press the On/Off button to start generating plasma.
X
While plasma is being generated, do not put your hand into the working area. This may
disturb the plasma discharge and cause skin irritations and might be slightly painful.