External supply temperature sensor
Temperature sensor
External supply line sensor (BT63) is installed, depend-
ing on the docking, according to the outline diagram
in this manual.
Install the temperature sensors using cable ties, with the
heat conducting paste and aluminium tape. Then insu-
late them with the supplied insulation tape.
NOTE
Sensor and communication cables must not be
placed near power cables.
Connect the supply temperature sensor (BT63) to any
AUX input on the input board in the main product.
SMO 40
AA3-X6
LEK
OPT 10 | GB
1
2
3
4
5
6
7
8
9
BT63
10
AA3-X6

Program settings

Program setting for OPT 10 can be performed via the
start guide or directly in the menu system in NIBE the
heat pump/indoor module/control module.
Caution
Also, see the Installer Manual for the heat
pump/indoor module/control module.

Start guide

The start guide appears upon first start-up after heat
pump installation, but is also found in menu 5.7.

Menu system

If you do not make all settings via the start guide or need
to change any of the settings, this can be done in the
menu system.
Menu 5.2.4. -system settings
Activating/deactivating of accessories.
Select: GBM communication module
Menu 5.3.15 - GBM communication module
Setting the start values for the gas boiler.

Technical data

OPT 10
Rated voltage
VDC (mA)
Dimensions
mm
Part No.
EAN no.
12 VDC (45-80mA)
80x80x30
067 513
7331421335369
17