RS10
P09
Slowdown distance when closing
Slowdown distance when
P10
opening
P13
Opening deceleration speed
P14
Closing deceleration speed
P15
Motor force
Force on obstacle detection
P16
(parameter can only be used
with encoder)
P17
Braking
x4
P18
Gate opening direction
Selects the operation of the
P20
second radio channel
P21
Channel 2 output activation time
P22
Pedestrian opening distance
P24
Break-out on starting
Manned, APCH controls opening
by keeping the button pressed,
P25
PED controls closing by keeping
the button pressed
6.5 - DEF
: Used to take the control unit to the default parameters, press and release the OK button until the display shows 4 dots to confirm the ope-
ration.
6.6 - CNT:
used to view the number of openings followed by the gearmotor, the first counter A displays the number of absolute operations, the second
counter P displays the operations performed after a reset controlled by the installer. This is shown in the following example:
x6
Pressing the UP button 6 times displays CNT (counter)
Press the OK button, the display shows the letter A (absolute counter cannot be reset) the number that follows should be multiplied by 10000
Press the UP button, the display shows the number to be added to get the total openings performed by the motor: absolute number =
(000*10000)+(7000)= 7000
Press the UP button, the display shows the letter P (partial counter can be reset) the number that follows should be multiplied by 1000
Press the UP button, the display shows the number to be added to get the openings after resetting the partial counter: partial number =
(000*10000)+(1000)= 1000, this means that it was reset on 6000 openings. To reset the partial counter, press and hold the OK button for at least 5
seconds until the display shows oooo to confirm the operation.
From 0 to 100%
0%= no slowdown when closing
100% = slowdown for the whole closing distance
From 100 to 0%
100%= no slowdown when opening
0% = slowdown for the whole opening distance
From 0 to 100%
0% = minimum slowdown speed
100% = maximum slowdown speed
From 0 to 100%
0% = minimum slowdown speed
100% = maximum slowdown speed
From 0 to 100%
0%= minimum force
100% = maximum force
From 0 to 100%
0% = minimum force (maximum obstacle sensitivity)
100% = maximum force (minimum obstacle sensitivity)
From 0 to 25
0 = minimum braking force
25 = maximum braking force
L = gate opening to the left
R = gate opening to the right
2CAN= activates the 2CH output
PEDO = controls pedestrian opening while the 2CAN output fun-
ctions as a courtesy light timed at 60 seconds
From 1 to 60 seconds
From 0 to 100% of total gate travel
OFF = gate starts with the force regulated with parameter P15
ON = gate starts for 1 second at maximum power to then return to
the force regulated with parameter P15
OFF: function disabled
ON: function active if the safety devices are open (PHOTO and STPA)
gate starting is delayed by 3 seconds from actuating the button
x5
EN
30%
70%
45%
45%
50%
50%
5%
L
PEDO
1 sec.
50%
ON
OFF
25