Herunterladen Inhalt Inhalt Diese Seite drucken

Vimar Elvox RS10 Installations- Und Benutzerhandbuch Seite 26

Leiterplatte 230 vac mit display für schiebetorantrieb
Vorschau ausblenden Andere Handbücher für Elvox RS10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 58
RS10
- even with the gate not closed, press the OK button to enter advanced travel programming mode, the display will indicate APCH
- press and release the AP/CH button, the gate closes if it is not in the closed position; once it reaches the closing limit switch (closing limit switch
engaged, FCCH LED off), the display indicates the OPN message and the gate opens
- press and release the AP/CH button to determine the starting point of deceleration on opening
- the gate continues slowing down until the opening limit switch trips (the FCAP LED goes out), the display indicates the CLS message and the gate
starts to close
- press and release the AP/CH button to determine the starting point of deceleration on closing
- the gate continues slowing down until the closing limit switch trips (the FCCH LED goes out)
- the display indicates the PED message and the gate opens
- press and release the AP/CH button to determine the pedestrian opening distance
- the gate continues until the closing limit switch trips (the FCCH LED goes out) the display reads END, the travel has been saved correctly.
6.4 - PAR:
Used to modify all the parameters of the control unit, press the OK button to display the list of parameters, the display will show P01
(parameter number 1), the UP or DOWN button lets you scroll through the list of parameters (see parameter table).
x4
Parameter table
Parameter
Description
number
P01
Enables automatic closing
P02
Sets the automatic closing time
P03
APCH input operation
P04
Pre-flash
P05
Instant closure
P06
Logic of the STPA input
P07
AUX output operating mode
Enables checking the safety
P08
inputs
24
Press the pushbutton
until the parameter to
change
Settable values
ON/OFF
2-600 seconds
1= when opening, APCH input not active (condo)
x5
2 = APCH as sequential (open, stop, close, open)
3 = APCH as sequential (open, close, open...)
4 = APCH commands only opening, APED commands only closing
OFF= pre-flash off
ON= pre-flash on (flashing output activated for 3 seconds before the
movement of the gate)
ON= with the gate opening or open on disengaging the PHOTO input
(terminal 22) the gate closes 3 sec. after completing opening
OFF= normal operation
0= microswitch sensitive edge (the operation of this input immedia-
tely reverses the movement for 1.5 seconds and then stops the gate
1= resistive sensitive edge (balanced with 8.2Kohm resistance), the ope-
ration of this input immediately reverses the movement for 1.5 seconds
and then stops the gate
2= photocell as internal protection (if engaged it stops the gate, until
it is disengaged, then it continues opening)
OFF = flashes slowly during gate opening and is on steady when the
gate is open and stationary, flashes rapidly during closing and is off
when the gate is closed and stationary
ON = flashes while the gate is moving and is off when the gate is
stationary
0 = input check off
1= check only on PHOTO input
2= check only on STPA input
3 = check on PHOTO and STPA inputs
EN
Default
Modified
value
value
OFF
60 seconds
1
ON
OFF
0
OFF
0

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis