6- Programming
Note:
The rapid programming of the travel of the gate leaves is only available for motors operating with an encoder.
For motors operating without encoder, only complete gate leaf travel programming is available.
6.1- Rapid procedure for learning the travel for automatic gate systems with double swing leafs with encoder.
The reduced procedure allows saving the travel, with distances for slowing down of 30% the total travel, while the gate leaf delays are fixed at 3 sec for
opening and 6 sec for closing.
- Press and hold learning push-button P2 for at least 3 seconds
- The DL6 LED starts flashing slowly
- Release push-button P2
- Activate APCH: M2 closes at low speed until the mechanical stop
- M1 closes at low speed until the mechanical stop
- M1 opens at low speed until the mechanical stop
- M2 opens at low speed until the mechanical stop
- M2 closes at normal speed and then slows down and continues until the mechanical stop for closing
- M1 closes at normal speed and then slows down and continues until the mechanical stop for closing
- The control panel performs a complete opening and closing cycle with the default slowdown distance and offsets.
- The DL6 LED will turn off to confirm successful programming.
With this programming the slowdown distance is set to 30% of the saved travel and an opening delay of 3 seconds and a closing delay of 6 seconds.
N.B.: With this type of programming the mechanical stops are necessary both when opening and closing and during programming and in normal operation.
6.2- Rapid procedure for learning the travel for automatic gate systems with a single swing leaf with encoder.
The reduced procedure allows you to save the travel, with slowdown distances of 30% compared to the total travel:
- Connect the motor to terminals 1 and 2 (output for motor M1), the control panel automatically configures itself for single leaf operation.
- Press and hold learning pushbutton P2 for at least 3 seconds
- The DL6 LED starts flashing slowly
- Release pushbutton P2
- Activate APCH: M1 closes at low speed until the mechanical stop
- M1 opens at low speed until the mechanical stop
- M1 closes at normal speed and then slows down and continues until the mechanical stop for closing
- The control panel performs a complete opening and closing cycle with the default slowdown distance.
- The DL6 LED will turn off to confirm successful programming.
With this programming, the slowdown distance is set to 30% of the saved travel.
N.B.: With this type of programming the mechanical stops are necessary both when opening and closing and during programming and in normal operation.
6.3- Complete procedure for learning the travel for automatic gate systems with double swing leafs, with encoder.
The complete procedure allows saving the travel, with the ability to customize the slowdown distance and the offset both when opening and closing the 2
motors.
- Press learning pushbutton P2 and keep it pressed
- The DL6 LED starts flashing
- Do not release the P2 button and hold it down for another 2 seconds
- The DL6 LED starts flashing faster
- Release pushbutton P2
- Activate APCH: M2 closes at low speed until the mechanical stop
- M1 closes at low speed until the mechanical stop
- Part M1 opening at normal speed
- When you want the gate to move more slowly activate APCH
- The slow speed phase begins for motor M1.
- When M1 reaches full opening activate APCH or wait for the gate leaf to reach the mechanical stop
- The second gate leaf M2 opens at normal speed
- When you want the gate to move more slowly activate APCH
- The slow speed phase begins for motor M2.
- When the gate leaf reaches full opening activate APCH or wait for the gate leaf to reach the mechanical stop
- The second gate leaf M2 closes at normal speed
- When you want the gate to move more slowly activate APCH
- The slow speed phase begins for motor M2.
- When the gate leaf reaches the mechanical stop for closing: the first gate leaf M1 will start closing at normal speed
- When you want the gate to move more slowly activate APCH
- The slow speed phase begins for motor M1.
- When the gate leaf reaches the mechanical stop for closing, the first gate leaf M1 will start opening and as soon as you decide that the gate leaf offset time
is sufficient activate APCH again: the second gate leaf will M2 start opening
- When the 2 gate leafs have completed opening, M2 will start closing as soon as you decide that the gate leaf offset time is sufficient activate APCH again:
the first gate leaf M1 will start closing.
- When the 2 gate leaves have completed closing, the DL6 LED will turn off to confirm successful programming.
N.B.: With this type of programming the mechanical stops are necessary when closing both during programming and in normal operation.