e l e C t r o n i C r o o m
t h e r m o s t a t
1
i n s tal l at ion
Fix the thermostat on the wall, at 1,5 mt height
from the floor and away from the kitchen, heat
sources, windows, doors etc..
remove the body of the thermostat from the
base as shown in the illustration.
turn the cover-plate downwards.
attention: Pay attention that the body of the
thermostat is well fixed on the wall, on a plane
surface and without strains.
2
e l eCt r iC Conne Ctio ns
Connect the C60 to the power supply and to
the user as shown in the scheme aside.
in
Winter
mode,
temperature increases, the relay switches
the terminal 3-1 and closes 3-2.
the terminal 2 is voltage free and can be
used for signals or other purposes.
3
F iX th e b oDY onto the Pl ate
4
s el eCtion o F the o Perati Ve
m o De : Wint e r – oFF – sUmmer
the C60 has a switch that allows to choose
the operative mode
sUmmer (for cooling systems);
Winter (for heating systems);
and oFF (system oFF).
When the red leD is on, it means that the
relay is operating to supply heat (switch in
Winter position) or cool (switch in summer
position).
t eC hn iCal CharaCteris ti Cs
in compliance with the en 60730-1 and parts two specs
Contact rating 6 (1,5) a 250 Vac
micro-disconnection (1b)
no-load switching contact
t45 (max room temperature measurable)
setting range 6 to 30°C
intervention differential 0,5 K
thermal gradient 4 K/h.
(double insulation).
e n g l i s h
when
the
room
for round flush-mounting box
b 60 mm
a 83,5 mm
for rectangular flush-mounting
box type 503 (three modules)
4
1
2
3
4
UTILIZZATORE
user *
*pump, burner, zone valve
with spring return
temperature knob regulator
Winter
oFF
sUmmer
switch
Pollution degree 2.
Protection degree iP20.
Voltage: 230V c.a. 50hz.
max impulse Voltage: 4000V.
max. dissipated power 1Va.
red led showing the relay operation.
Winter - oFF - sUmmer switch.
C60
!
Warning!
the thermostat
shall be installed
only by qualified
5
personnel, in
strict compliance
with the law
regulations in
force.
when the
leD is on,
the relay is
operating