Dry vacuuming

Vacuuming up dust deposits
– To switch on the dust extractor, set the
mode selector switch (5) to the "extraction"
symbol.
– To switch off the dust extractor, set the
mode selector switch (5) to the "switch off"
symbol.
Extracting dust that accumulates from working power
tools (see figure H)
There must be a sufficient air exchange rate (L) in the
u
room when the exhaust air comes back into the room.
Be aware of the corresponding national regulations.
The dust extractor has an electric socket with a protective
earth contact (3), which can be used to connect an external
power tool. Observe the maximum permitted load of the
connected power tool.
– Fit the extraction adapter (19) Fitting the dust extraction
adapter.
– Insert the extraction adapter (19) into the dust extraction
outlet of the power tool.
Note: When working with power tools that have a low air
feed into the vacuum hose (e.g. jigsaws, sanders, etc.), the
false air intake (32) of the extraction adapter (19) must be
opened. Only then can the semi-automatic filter cleaning
(SFC+) system work without any problems.
To do this, turn the ring above the false air intake (32) until
the opening is at its maximum size.
– To activate the automatic start/stop
function of the dust extractor, set the
mode selector switch (5) to the "auto-
matic start/stop" symbol.
– To activate the dust extractor, switch on the power tool
that is plugged into the electric socket (3). The dust ex-
tractor will start automatically.
– To stop dust extraction, switch the power tool off.
The automatic start/stop run-on function will run for up
to 15 seconds longer in order to extract the remaining
dust from the vacuum hose.
– To switch off the dust extractor, set the
mode selector switch (5) to the "switch
off" symbol.

Wet vacuuming

Do not use the vacuum cleaner to vacuum combustible
u
or explosive liquids, such as petrol, oil, alcohol or
solvents. Do not vacuum hot or burning dust. Do not
operate the vacuum cleaner in areas subject to explo-
sion hazards. Dust, vapours and liquids can ignite or ex-
plode.
The vacuum cleaner must not be used as a water
u
pump. The vacuum cleaner is designed for vacuuming air
and vacuuming water mixtures.
Bosch Power Tools
Note: The requirements for the degree of penetration (dust
class L) have only been verified for dry vacuuming.
Steps to Take before Wet Vacuuming
– Remove the disposal bag (23) or dust bag if necessary.
Note: Use a wet filter bag (accessory), which separates li-
quid from solids, to make disposal easier when vacuuming
water-solid mixtures.
– Place the rubber lip (26) into the floor nozzle (28). (see
"Fitting the rubber lip (wet vacuuming) (see figure F)",
page 20)
– Switch off semi-automatic filter cleaning (SFC+) (see
"Semi-automatic filter cleaning (see figure I)", page 21).
Vacuuming up liquids
– To switch on the dust extractor, set the mode selector
switch (5) to the "extraction" symbol.
The dust extractor is equipped with fill level sensors (35).
The dust extractor shuts down if the maximum fill level has
been reached. Set the mode selector switch (5) to the
"switch off" symbol.
Note: When extracting non-conductive liquids (e.g. drilling
emulsion, oils and fats), the dust extractor will not switch off
when the container is full. The fill level must be constantly
monitored and the container emptied in good time.
– To switch off the dust extractor, set the mode selector
switch (5) to the "switch off" symbol.
– Empty the container (1).
To prevent mould growth after wet vacuuming:
– Remove the flat-pleated filter (24) and leave this to dry
thoroughly.
– Remove the top part of the dust extractor (8), open the
filter cover (34) and leave both elements to dry thor-
oughly.
Semi-automatic filter cleaning (see figure I)
The filter cleaning function should be used regularly, and at
the very latest when the suction power is no longer suffi-
cient.
How often filter cleaning needs to be carried out will depend
on the type and quantity of dust that has been extracted.
With regular use, the maximum conveying capacity will be
maintained for longer.
During semi-automatic filter cleaning (SFC+), the air flow is
reversed to clean deposited dust from the flaps of the flat-
pleated filter.
A pleated filter with surface dirt is still fully functional. It is
not necessary to clean the flat-pleated filter manually by
shaking or blowing it out; this may even damage the filter.
Note: Semi-automatic filter cleaning is activated at the fact-
ory (SFC+ switch (18) in position I).
– Actuating SFC+ filter cleaning
Use the palm of your hand to close the opening in the
nozzle or vacuum hose.
Or, if the SFC+ module (20) is fitted:
Push the actuator (33) down for approximately 10
seconds.