Herunterladen Diese Seite drucken

Nibe PCM 40 Installateurhandbuch Seite 23

Passive kühlung
Vorschau ausblenden Andere Handbücher für PCM 40:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connecting communication
This accessory contains an accessories card (AA5) that
must be connected directly to the heat pump on the in-
put card (terminal block AA3-X4).
If several accessories are to be connected or are already
installed, the following instructions must be followed.
The first accessory card must be connected directly to
the heat pump's terminal block AA3-X4. The following
cards must be connected in series with the previous card.
The communication cable (W102, length 2,5 metres) is
factory fitted and connected according to the table be-
low.
Colour
Heat pump
(AA3-X4)
White (A)
Brown (B)
Green (GND)
EB100
AA3-X4
AA3-X4
A
15
B
14
GND
13
F1145/F1155
Accessory card 1
AA5-X4
A
1
B
2
GND
3
A
AA5-X4
4
B
5
GND
6
7
8
Accessory card 2
AA5-X4
A
1
B
2
GND
3
AA5-X4
A
4
B
5
GND
6
7
8
Connecting the supply
PCM 40/42 is factory fitted with power cable and plug
(W101, length 3,0 metres).
PCM 40/42 | GB
Another access-
ory board (AA5-
X4)
15
4
14
5
13
6
AA3-X4
F1245/F1255
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
-X8
-X2
-X4
1
2
3
4
5
6
7
8
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
-X8
-X2
-X4
1
2
3
4
5
6
7
8
Overview accessory board
24
23
-X8
-X2
-X4
1
2
3
4
5
6
7
8
External blocking
Use cable type LiYY, EKKX or similar.
A contact (NO) can be connected to AA5-X2:23-24 to
block cooling operation. When the contact closes, cool-
ing operation is blocked.
External blocking
External
Unit box
24
23
22
AA5-X2
Connecting sensors
The sensor EQ1-BT25 must be connected to one of the
heat pump's AUX inputs.
-X9
9
1
8
7
Selectable inputs on the input board for these functions
6
5
4
3
are:
2
1
-X10
AUX1
-X1
N
L
PE
PE
AUX2
AUX3
AUX4
AUX5
-X9
9
1
8
When the sensor is connected to one of five special
7
6
5
4
outputs, the correct function must be selected for the
3
2
1
-X10
correct connection in the heat pump's software (EQ1-
-X1
N
BT25).
L
PE
PE
AA5-X2
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
21
20
19
18
17
16
15
X6:9-10
X6:11-12
X6:13-14
X6:15-16
X6:17-18
AA5-X9
-X9
9
4
3
2
1
8
7
6
5
4
3
2
1
-X10
-X1
N
L
PE
PE
14
13
23

Quicklinks ausblenden:

Werbung

Kapitel

loading

Diese Anleitung auch für:

Pcm 42