Herunterladen Inhalt Inhalt Diese Seite drucken

Electrolux RCW 42 DC Installation, Bedienung Und Wartung Seite 7

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

C
ONNECTING TO A SOLAR GENERATOR SYSTEM
For connection to mains, fit a commonly used type of mains plug, corresponding to the socket to the connection
cable of the box. Take care that the appliance is properly earthed. (grounded plug and socket)
Note : These connections should only be done by an authorized electrical technician.
2
A
1
B
F
To start
, turn the selector switch 1 to position B. The setting of the thermostat knob 2 is without any
REEZING
importance, because this thermostat is out of use during freezing. The freezing function is regulated by an internal,
fixed themostat.
E
LECTRICAL CONNECTION
C
, F
ONTROLS
UNCTIONS
On the control panel you will find 2 control knobs :
the selector switch 1 and
the thermostat knob 2
With the selector switch 1 you can choose between two functions :
A = refrigerating
B = freezing
R
For
, turn the selector switch 1 to position A. A temperature regu-
EFRIGERATION
lation with the thermostat knob 2 can only be attempted, when the selector switch is
in position A. Turn the thermostat knob in clockwise direction to position „7/MAX". After
a sufficient period of maximum cooling, the thermostat knob 2 can be turned in anti-
clockwise direction to a position between MIN and MAX to reach the desired tempera-
ture. This temperatur will be maintained by the thermostat.
NOTE : If the thermostat 2 is set to position 0, the refrigeration function is disabled,
even if the selector switch 1 is still in position A.
Solar power pack and battery box
with charge regulator
For installation and connections refer to the
Installation instructions from the energy system
supplier.