The room in which the equipment is to be installed must be dry and suitable ventilated, avoiding direct exposure to
the sun or positionning near a heat source. The place must be protected against beatring rain and dust. A good air
circulation especially around the compressor is essential for a good operation. Keep the air vent openings of the
compressor cover always free from any obstructions.
The maximal permissible inclination of the appliance is :
for RCW42DC : 30°
for RCW42AC : 5°
C
ONNECTING TO A BATTERY
C
ONNECTING TO A CONVERTER
AC/DC - converters, automobile generators or similar
must always be connected to the battery poles.
T
HESE APPLIANCES MUST NEVER BE CONNECTED DIRECTLY
.
TO THE BOX
The leads must be connected using cable shoes and
screwed connections; joined leads must be avoided.
A
: The existing connection cable of the box must not be
TTENTION
prolongated. If a longer connection cable is absolutely necessary, the
cable cross-section must be increased according the table.
I
NSTALLATION
E
LECTRICAL CONNECTION
˜
RCW42DC
The appliance must always be directly connec-
ted to the poles of a battery :
Converter
Convertisseur
Umwandler
I
F CONNECTING TO THE WRONG POLES
OF THE ELECTRONIC UNIT WILL BLOW AND THE
ELECTRONIC UNIT MAY BE DESTRUCTED
cable cross-
- 5 -
RCW42DC :
max. 30°
RCW42AC :
max. 5°
PLUS TO PLUS
MINUS TO MINUS
˜
cable length in m
section
in mm
2
12V
2.5
2.5
4
4
6
6
10
10
16
16
,
THE FUSE
!
Converter
Convertisseur
Umwandler
24V
5
8
12
20
32