Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting To A Converter; Connecting To A Solar Generator System; Electrical Connection - Electrolux RCW 42 DC Installation, Bedienung Und Wartung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

C
ONNECTING TO A CONVERTER
AC/DC - converters, automobile generators or
similar must always be connected to the battery
poles.
T
HESE APPLIANCES MUST NEVER BE CONNECTED
.
DIRECTLY TO THE BOX
The leads must be connected using cable shoes
and screwed connections; joined leads must be
avoided.
A
: The existing connection cable of the box must not be
TTENTION
prolongated. If a longer connection cable is absolutely necessary, the
cable cross-section must be increased according the table.
C
ONNECTING TO A SOLAR GENERATOR SYSTEM
For connection to mains, fit a commonly used type of mains plug, corresponding to the socket to the connection cable
of the box. Take care that the appliance is properly earthed. (grounded plug and socket)
Note : These connections should only be done by an authorized electrical technician.
E
C
LECTRICAL
ONNECTION
cable cross-
Solar power pack and battery
box with charge regulator
For installation and connections refer to the
Installation instructions from the energy system
supplier.
Energy consumption RCW50 DC :
without Icepack-Freezing
T
Amb
T
Amb
with Icepack-Freezing (4 Icepacks)
T
Amb
T
Amb
with Icepack-Freezing (8 Icepacks)
T
Amb
RCW50AC
- 6 -
˜
cable length in m
section
in mm
2
12V
2.5
2.5
4
4
6
6
10
10
16
16
= 32°C
0.46 kWh/24h
= 43°C
1.08 kWh/24h
= 32°C
1.01 kWh/24h
= 43°C
1.39 kWh/24h
= 43°C
1.53 kWh/24h
Converter
Convertisseur
Convertidor
Umwandler
24V
5
8
12
20
32