Herunterladen Inhalt Inhalt Diese Seite drucken

Introduction; Main Technical Specifications - Scale House AFWC30 Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1. INTRODUCTION

This manual was created to help you install and learn all about the functional possibilities of the AFWC and AFWD scales.
The scales should be sited in a location that will not degrade the accuracy.
Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning vents.
Avoid unsuitable tables. The tables or floor must be rigid and not vibrate. Do not place near vibrating machinery.
Avoid unstable power sources. Do not use near large users of electricity such as welding equipment or large motors.
Avoid high humidity that might cause condensation. Avoid direct contact with water. Do not spray or immerse the scales in
water.
Avoid air movement such as from fans or opening doors. Do not place near open windows.
Keep the scales clean.
Do not stack material on the scales when they are not in use.

2. MAIN TECHNICAL SPECIFICATIONS

Model
AFWC30
AFWC60
AFWC150
AFWD60
AFWD150
AFWD300
Stabilisation Time
Operative Temperature:
Power supply:
Battery life:
Recharge time:
Parameter Setup:
Display :
Case:
Load cell drive voltage:
Range of input signal
Load cells:
Programmable Zero range:
Programmable Auto zero at start-up:
WARNINGS
Plate
(dimensions in mm)
350x450
350x450
350x450
420x520
420x520
420x520
1 Seconds typical.
0°C - 40°C / 32°F - 104°F.
with fitted 240 Vac mains power adapter or with fitted battery
up to 90 hours of continuous use.
12 hours.
Calibration fully digital and programmable from the keyboard.
LCD backlit with 6 digits 24 mm high
ABS Plastic.
Max 5V/150mA.
0 mV/V - 3 mV/V.
up to 4 load cells with input resistance of 350 Ohm.
+/- 2, 4, 10, 20, 50, 100 % of max load capacity.
+/- 0, 2, 5, 10, 20 % of max load capacity.
Capacity kg
30
60
150
60
150
300
.
4
Division g
Resolution g
10
20
50
20
50
100
0,05
0,1
0,25
0,1
0,25
0,5