bEEP
ACOUSTIC ALARM
By pressing ZERO it's possible to decide whether the acoustic alarm should enable when the "OK" symbol is on or
when the "HI" or "LO" symbols are on.
Press TARE to change the options:
bP 1
acoustic alarm disabled
bP 2
active acoustic signal with active "OK" symbol.
bP 3
active acoustic signal with active "HI" or "LO" symbol.
Confirm with ZERO or press PRINT/M+ to exit without confirming.
7.7 "F5 Prt" – SETTING MANUAL OR AUTOMATIC TOTALISATION
The accumulation operation, normally done manually through the PRINT/M+ key, can be made automatically when
the weight stability is reached. The choice of the execution mode of the totalisation is executed in this parameter.
Press TARE to select one of the suggested values:
P Prt
Manually through the PRINT/M+ key.
P AUto Automatically upon weight stability.
Confirm with ZERO or press PRINT/M+ to exit without confirming.

7.8 "F6 rSt"

For use of the manufacturer.
7.9 "ProG" – SCALE CONFIGURATION
By pressing ZERO it's possible to access the scale configuration menu. One is asked to enter the password.
To enter the menu press the U, PRINT/M+, and TARE keys, one after the other:
The display shows the first parameter, "P1 REF".
7.9.1 "P1 REF" – METRIC PARAMETERS (*)
(*) In case of approved instrument the parameter is not accessible.
AZn
By pressing ZERO one sets the zero tracking, in other words, scale's thermal drift compensation parameter;
the set value corresponds to the number of divisions which is cleared.
Press TARE to select one of the suggested divisions: oFF, 0.5d, 1d, 2d, 4d.
0Auto
By pressing ZERO one sets the weight percentage for the automatic acquisition of the gross zero at start-up. If
at the start-up a weight is detected that is within the programmes percentage of the total capacity, it will be
cleared; if the weight is not within this tolerance, the display, after a few instants, shows the current weight.
Press TARE to select one of the suggested percentages: +/- 0, 2, 5, 10, and 20 % of the max. capacity.
Confirm with ZERO or press PRINT/M+ to exit without confirming.
0rAnG
By pressing ZERO one sets the weight percentage for the manually acquiring the gross zero; if, in the normal
weighing phase, by pressing ZERO, a weight within the programmed percentage of the total capacity, it will be
cleared.
Press TARE to select one of the suggested percentages: +/- 2, 4, 10, 20, 50, or 100 % of the max. capacity.
Confirm with ZERO or press PRINT/M+ to exit without confirming.
SPEED
By pressing ZERO one sets the reading speed of the ADC converter; the set value corresponds to the number
of readings made in a second.
Press TARE to select one of the suggested reading speeds: 7.5, 15, 30, 60.
Confirm with ZERO or press PRINT/M+ to exit without confirming.
ZERO TRACKING
AUTOMATIC ZERO AT START-UP
MANUAL ZERO RANGE
SETTING ADC CONVERTER READING SPEED
14