4. Prepare a disinfectant bath consisting of water and Incidin
(temperature: max. 30 °C, concentration: 1.5 %)
5. Place all parts that require disinfection into the disinfectant bath
(duration: 15 minutes).
6. Thoroughly rinse all parts under running water.
NOTICE
i
i
After cleaning and disinfecting silicone half masks, rinse each
part for 10 minutes.
7. Allow all parts to air-dry or be dried in the drying cabinet
(temperature: max. 60 °C). Keep out of direct sunlight.
4.3

Maintenance work

4.3.1
Inspecting the half mask
Inspect all parts for damage, brittleness or deformation
WARNING
!
The harness must be undamaged (e.g. not porous or
cracked) to ensure that the half mask fits tightly and prevent
risk of poisoning! Replace if required.
4.3.2
Disassembling the half mask (see page 5, Figure C)
NOTICE
i
i
The following procedure applies only to X-plore 4740 and
X-plore 4790.
1. Press the sealing profile (1) and fastening nubs (2) out of the cap.
2. Remove the cap from the mask body.
®
1)
Incidin
is a registered trademark of Ecolab USA Inc.