Stage 2
• Drain the cleaning solution from the internal reservoir by removing the rear drain cap and plug.
• Add fresh water to the Max. permit water volume line.
• With the stand-by mode, keep pressing ON/OFF button at least 5 seconds to activate the self-clean
mode again which will now act as a rinse.
• Upon completion of this final stage of the self clean process, the unit automatically changes to
stand-by mode. Proceed to drain the water from the internal reservoir by removing the rear drain
cap and plug. Leave the lid on the ice maker open to allow it to air dry.
NOTE: Please note if there is a water shortage during Self-cleaning mode, the unit will automatically
go into stand-by mode; If water bucket is fail to turn over, icon
ON/OFF button for more than 5 seconds to release self-cleaning mode to change for other operations.
Cleaning and stop use.
• Make sure to unplug the appliance before cleaning and long time off use.
• Use a damp cloth to clean both the interior and exterior of the appliance.
• Water tank cleaning.
• Unscrew the nut of water outlet, drain off the water.
• Pour clean water into the water tank, use a clean cloth to wipe water tank around. Pour clean water
again until the flowing out water is clean, and then drain off water and grip the nut.
• Do not use organic solvents, boiling water, cleaning agents, strong acids, strong acid and Alkali etc
substances for cleaning.
• If ice machine will be off use for a long time, you should unplug the appliance, drain off the water
and dry the appliance with a clean cloth, store the ice maker in a clean place.
Faults
WORK indicator is not
light.
ICE FULL indicator is
light.
Malfunction indicator
light flashes.
WATER absence indi-
cator flashes.

Troubleshooting

Reason
Power Source is not
switched on.
Ice fullness.
Low-temperature
protection(temperature is
lower than 5°C).
Ice making box reset in bad
condition.
Absence of water.
Water supply system or
components damaged.
will be on, you need to long press
Treatment
Check the power supply matches
Check the power cord is connected correctly
Internal components are damaged. Mainte-
nance in professional department.
Remove the full Ice cube.
Move the Ice maker to a warmer place,
where the ambient temperature is higher
than 5°C.
Check whether any foreign body stuck the
ice making box.
Internal components are damaged. Mainte-
nance in professional department.
Pour the storage room into clean water,
push the key to eliminate the failure.
Maintenance in professional department